{"product_id":"acs712-acs724-module-5a-20a-30a-range-current-detection-board-hall-current-sensor-05b","title":"ACS712 ACS724 module 5A 20A 30A range current detection board Hall current sensor 05B","description":"\u003ch1\u003eSPECIFICATIONS\u003c\/h1\u003e\u003cp\u003e\u003cspan\u003eApplication\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eRange current detection board\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eBrand Name\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNONE\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eChoice\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eyes\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eCondition\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNew\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eDissipation Power\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e5V\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eHigh-concerned chemical\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003enone\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e-40℃~+85℃\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOrigin\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eMainland China\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003ePackage\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eDIP\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eSupply Voltage\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e5V\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eType\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eModule\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eis_customized\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eYes\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003esemi_Choice\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eyes\u003c\/span\u003e\u003c\/p\u003e\u003cdiv class=\"detailmodule_html\"\u003e\u003cdiv class=\"detail-desc-decorate-richtext\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:20px;color:#ff0000;\"\u003eACS712\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:20px;color:#ff0000;\"\u003e5A Product Parameter：\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size:20px;\"\u003e1. Current sensor chip:ACS712ELC-5A;\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size:20px;\"\u003e2. Pin 5V power supply, on-board power indicator;\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size:20px;\"\u003e3. The module can be measured plus or minus 5 amps, corresponding to the analog output 66mV\/A;\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size:20px;\"\u003e4. There is no the detection current through, the output voltage is VCC\/2;\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size:20px;\"\u003e5. PCB board size:31 (mm)x13(mm)；\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003c\/strong\u003e \u003cp\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size:20px;\"\u003eNote: ACS712 Hall detection principle, when you use to avoid magnetic field impact this!\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:20px;color:#ff0000;\"\u003e20A Product Parameter：\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size:20px;\"\u003e1. Current sensor chip: ACS712ELC-20A;\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size:20px;\"\u003e2. Pin 5V power supply, on-board power indicator;\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size:20px;\"\u003e3. The module can measure the positive and negative 20 amps, corresponding to the analog output 100mV\/A;\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size:20px;\"\u003e4. There is no the detection current through, the output voltage is VCC\/2;\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size:20px;\"\u003e5. PCB board size:31(mm)x13(mm)；\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003c\/strong\u003e \u003cp\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size:20px;\"\u003eNote: ACS712 Hall detection principle, when you use to avoid magnetic field impact this!\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:20px;color:#ff0000;\"\u003e30A Product Parameter：\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size:20px;\"\u003e1. The current sensor chips: ACS712ELC-30A;\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size:20px;\"\u003e2. Pin 5V power supply, on-board power indicator;\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size:20px;\"\u003e3. The module can measure the positive and negative 30 amps, corresponding to the analog output 66mV \/A;\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size:20px;\"\u003e4. No test current through the output voltage is VCC \/2;\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size:20px;\"\u003e5. PCB board size: 31 (mm)x13 (mm)；\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003c\/strong\u003e \u003cp\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size:20px;\"\u003eNote: ACS712 Hall detection principle, when you use to avoid magnetic field impact this!\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003cspan style=\"font-size:20px;\"\u003e \u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/Sf5d2652c5e574d04902b6551b5554a13f.jpg\" style=\"width:1000px;\" data-src=\"https:\/\/ae01.alicdn.com\/kf\/Sf5d2652c5e574d04902b6551b5554a13f.jpg\"\u003e\u003c\/p\u003e\u003c\/div\u003e\n\u003cbr\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/div\u003e\u003c\/div\u003e\r\n","brand":"Yoeruyo","offers":[{"title":"ACS712 20A","offer_id":55440682582315,"sku":"14:350852#ACS712 20A","price":7.43,"currency_code":"USD","in_stock":true},{"title":"ACS712 5A","offer_id":55440682615083,"sku":"14:1202#ACS712 5A","price":8.28,"currency_code":"USD","in_stock":true},{"title":"ACS712 30A","offer_id":55440682647851,"sku":"14:351074#ACS712 30A","price":8.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/5744\/8747\/files\/Sf5093dc739e942989e7bb4d3cee44f277.webp?v=1788745545","url":"https:\/\/yoeruyo.com\/products\/acs712-acs724-module-5a-20a-30a-range-current-detection-board-hall-current-sensor-05b","provider":"Yoeruyo","version":"1.0","type":"link"}