{"product_id":"dc-12v-24v-8-isolated-input-8-output-din35-c45-rail-box-uart-rs485-relay-module-modbus-rtu-control-switch-board-1","title":"DC 12V 24V 8 Isolated Input \u0026 8 Output DIN35 C45 Rail Box UART RS485 Relay Module Modbus RTU Control Switch Board","description":"\u003ch1\u003eSPECIFICATIONS\u003c\/h1\u003e\u003cp\u003e\u003cspan\u003eBrand Name\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eeletechsup\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eChoice\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eyes\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eCondition\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNew\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eHigh-concerned chemical\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003enone\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOrigin\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eMainland China\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eSupply Voltage\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e12V\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eType\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eRelay\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eis_customized\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eYes\u003c\/span\u003e\u003c\/p\u003e\u003cdiv\u003e\u003cspan style='font-size:22px;font-family:\"times new roman\", times, serif'\u003e\u003cspan style='color:rgb(255, 0, 0);font-size:22px;font-family:\"times new roman\", times, serif'\u003eProduct Name:  DC 12V 24V 8 Isolated Input \u0026amp; 8 Output DIN35 C45 Rail Box UART RS485 Relay Module Modbus RTU Control Switch Board\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_html\"\u003e\u003cdiv class=\"detail-desc-decorate-richtext\"\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n\u003cdiv\u003e\u003cspan style='font-size:22px;font-family:\"times new roman\", times, serif'\u003ePackage inlcuded:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e1PCS DC 12V\/24V 8 Input \u0026amp; 8 Output RS485 Relay Module\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\u003cimg src=\"http:\/\/ae01.alicdn.com\/kf\/H52e4ca16463247e381d6dc3b69381cc4r.jpg\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\u003cspan style='font-size:22px;font-family:\"times new roman\", times, serif'\u003eDescription: \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n\u003cdiv style=\"font-size:14pt\"\u003e\u003cdiv style='font-family:\"times new roman\"'\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cspan style='color:rgb(0, 0, 255);font-size:22px;font-family:\"times new roman\", times, serif'\u003e\u003cspan style='font-size:22px;font-family:\"times new roman\", times, serif'\u003e\u003cspan style='color:rgb(255, 0, 0);font-size:22px;font-family:\"times new roman\", times, serif'\u003e1: DC 12V (12V Version), DC 24V (24V Version)\u003cbr\u003e \u003cbr\u003e2: Standby current (all relays closed) 13MA, 1 relay open 41MA, 2 relays open 69MA, 3 relays open 95MA,4 relays open 122MA,5 relays open 149MA,6 relays open 174MA, 7 relays open 198MA,8 relays open 225MA\u003cbr\u003e \u003cbr\u003e3 8 photoelectric isolation Input ports (NPN  low level active ), the input and output relationship can be set to associated (default) and non-associated through commands.\u003cbr\u003e \u003cbr\u003e4: ''open'' ''close''  ''Momentary'' ''Self-locking'' ''Interlock'' ''Delay'' 6 Commands\u003cbr\u003e \u003cbr\u003e5: MODBUS RTU command, Support 03 06 16 function code\u003cbr\u003e \u003cbr\u003e6: Under the ''Delay'' command ,the maximum delay is 255 seconds;\u003cbr\u003e \u003cbr\u003e7 MODBUS commands can be made serial HyperTerminal (serial assistant)  OR ''Modbus Poll'' Enter; \u003cbr\u003e \u003cbr\u003e8 Under the MODBUS command mode, it can support up to 64 devices in parallel\u003cbr\u003e \u003cbr\u003e9 The default baud rate is 9600BPS. The baud rate can be selected through jumpers: 2400 4800 9600 19200BPS\u003cbr\u003e \u003cbr\u003e10  Size: 136 * 72 * 20mm(Only PCB Board);140 * 88* 42mm(with Din Rail Box)\u003cbr\u003e11 Weight: 134g(Only PCB Board);223g(with Din Rail Box)\u003cbr\u003e \u003cbr\u003e12 Maximum load: 10A \/ 250VAC, 10A \/ 125VAC, 10A \/ 30VDC, 10A \/ 28VDC, 10A \/ 12VDC\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style='color:rgb(0, 0, 255);font-size:22px;font-family:\"times new roman\", times, serif'\u003e\u003cspan style='font-size:22px;font-family:\"times new roman\", times, serif'\u003e\u003cspan style='color:rgb(255, 0, 0);font-size:22px;font-family:\"times new roman\", times, serif'\u003e\u003cbr\u003e \u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan style='color:rgb(0, 98, 177);font-size:26px;font-family:\"times new roman\", times, serif'\u003eFor more information, please Download instruction manual link:\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style='background-color:rgb(255, 255, 255);color:rgb(0, 0, 255);font-size:22px;font-family:\"times new roman\", times, serif'\u003e\u003cspan style='background-color:rgb(255, 255, 255);font-size:22px;font-family:\"times new roman\", times, serif'\u003e\u003cspan style='background-color:rgb(255, 255, 255);color:rgb(255, 0, 0);font-size:22px;font-family:\"times new roman\", times, serif'\u003ehttps:\/\/1drv.ms\/u\/s!AjrAGEbCBLlsgZM_LcNeMps9vo94XA?e=VSRe3z\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style='color:rgb(0, 0, 255);font-size:22px;font-family:\"times new roman\", times, serif'\u003e\u003cspan style='font-size:22px;font-family:\"times new roman\", times, serif'\u003e\u003cspan style='color:rgb(255, 0, 0);font-size:22px;font-family:\"times new roman\", times, serif'\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan style='color:rgb(0, 0, 0);font-size:26px;font-family:\"times new roman\", times, serif'\u003eDIN rail Box parameters:\u003c\/span\u003e\u003cspan style='color:rgb(0, 0, 255);font-size:22px;font-family:\"times new roman\", times, serif'\u003e\u003cspan style='font-size:22px;font-family:\"times new roman\", times, serif'\u003e\u003cspan style='color:rgb(255, 0, 0);font-size:22px;font-family:\"times new roman\", times, serif'\u003e\u003cbr\u003eProduct model: UM72\u003cbr\u003eColor: green\u003cbr\u003eWidth: suitable for PCB board width UM72(72mm)\u003cbr\u003eInsulation grade: flame-retardant VO grade\u003cbr\u003eBackplane length: suitable for 136 mm PCB boards\u003cbr\u003eNet weight: 99g\u003cbr\u003eInstallation: DIN35 and C45 rail\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg src=\"http:\/\/ae01.alicdn.com\/kf\/Hea87ea25867c4a4eae41b191a6b8e4f9Z.jpg\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv style='font-family:\"times new roman\";font-size:14pt'\u003e\u003c\/div\u003e\n\u003cdiv style='font-family:\"times new roman\";font-size:14pt'\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\u003cspan style='font-size:22px;font-family:\"times new roman\", times, serif'\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style='font-size:22px;font-family:\"times new roman\", times, serif'\u003ePLC IO expansion board\u003cbr\u003eSmart Home,Home Automation ,Wiser Home;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style='font-size:22px;font-family:\"times new roman\", times, serif'\u003ePTZ CCTV Camera\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style='font-size:22px;font-family:\"times new roman\", times, serif'\u003eSecurity Monitoring\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style='font-size:22px;font-family:\"times new roman\", times, serif'\u003eIdentification system;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style='font-size:22px;font-family:\"times new roman\", times, serif'\u003eMotor FW \u0026amp; BW\u003cbr\u003eAutomatic curtain control\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n\u003cspan style='color:rgb(51, 51, 51);font-size:22px;font-family:\"times new roman\", times, serif'\u003e\u003cspan style='font-size:22px;font-family:\"times new roman\", times, serif'\u003e\u003cstrong\u003eTypical applications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan style='color:rgb(51, 51, 51);font-size:22px;font-family:\"times new roman\", times, serif'\u003e\u003cspan style='font-size:22px;font-family:\"times new roman\", times, serif'\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cimg src=\"http:\/\/ae01.alicdn.com\/kf\/H0a0a24efeac34cd2b52eb48298e89f85M.jpg\" slate-data-type=\"image\"\u003e\u003cbr\u003e1 The dial switch (slave address) is invalid and can only control one module at a time.\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/ae01.alicdn.com\/kf\/Hb42ada636b254f14bca1ee78535f0e5cX.jpg\" slate-data-type=\"image\"\u003e\u003cbr\u003e\u003cimg src=\"http:\/\/ae01.alicdn.com\/kf\/H142dbf3e5f8d4c1898a14a4ea1dbd234o.jpg\" slate-data-type=\"image\"\u003e\u003cbr\u003eMODBUS RTU command mode (HEX), you can control a variety of ways: Serial Hyper Terminal Control (need to manually add the CRC), Modbus Poll software control (software automatically add the CRC), PLC or MCU process control\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Diagram:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\u003cimg src=\"http:\/\/ae01.alicdn.com\/kf\/Hf44d3d6339184b0fbe920bed94bec6b4L.jpg\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\u003cp\u003e1 DC 12V\/24 control circuit,Wiring diagram below. ''LOAD'' may be camera,LED lights, fans, motors and other DC 12V\/24V equipment\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\u003cimg src=\"http:\/\/ae01.alicdn.com\/kf\/Hc2ea9ed658b943e9b24852b94a29791bt.jpg\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e2 DC 1-110V OR AC 85-265V control circuit,Wiring diagram below(Note:If not DC 12V\/24V load, need another DC 12V\/24V power supply). ''LOAD'' may be LED lights, fans, motors Lights, fluorescent lights, solar water heaters and other DC AC equipmen\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\u003cspan style='font-size:22px;font-family:\"times new roman\", times, serif'\u003eTest Software(We offer a demo video):\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\u003cspan style='color:rgb(51, 51, 51);font-size:22px;font-family:\"times new roman\", times, serif'\u003eSerial HyperTerminal:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003eModbus Poll\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-size:medium;color:rgb(0, 0, 0)\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Yoeruyo","offers":[{"title":"12V with Rail Box","offer_id":55513917030699,"sku":"14:1052#12V with Rail Box","price":103.76,"currency_code":"USD","in_stock":true},{"title":"24V with Rail Box","offer_id":55513917063467,"sku":"14:200004890#24V with Rail Box","price":109.88,"currency_code":"USD","in_stock":true},{"title":"12V Only Board","offer_id":55513917096235,"sku":"14:1254#12V Only Board","price":88.36,"currency_code":"USD","in_stock":true},{"title":"24V Only Board","offer_id":55513917129003,"sku":"14:771#24V Only Board","price":85.04,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/5744\/8747\/files\/S2f76ad8f50344fa9a3f2d1d9d22429d6w_efada4f0-4307-46c9-8a13-985b8c5cb995.webp?v=1789008458","url":"https:\/\/yoeruyo.com\/products\/dc-12v-24v-8-isolated-input-8-output-din35-c45-rail-box-uart-rs485-relay-module-modbus-rtu-control-switch-board-1","provider":"Yoeruyo","version":"1.0","type":"link"}