{"product_id":"dc-5v-real-time-timing-delay-timer-relay-module-switch-control-clock-synchronization-multiple-mode-control-wiring-diagram","title":"DC 5V Real time Timing Delay Timer Relay Module Switch Control Clock Synchronization Multiple mode control Wiring diagram","description":"\u003ch1\u003eSPECIFICATIONS\u003c\/h1\u003e\u003cp\u003e\u003cspan\u003eApplication\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eComputer\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eBrand Name\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eSTJF\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eChoice\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eyes\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eCondition\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNew\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eDissipation Power\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e1\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eHigh-concerned chemical\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003enone\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e-40-+85\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOrigin\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eMainland China\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003ePackage\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eDIP\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eSupply Voltage\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e1\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eType\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eVoltage Regulator\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eis_customized\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eYes\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003esemi_Choice\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eyes\u003c\/span\u003e\u003c\/p\u003e\u003cdiv class=\"detailmodule_html\"\u003e\u003cdiv class=\"detail-desc-decorate-richtext\"\u003e\n\u003cdiv\u003e\n\u003cspan style=\"font-size:26;\"\u003eDescription: \u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size:26;\"\u003eReal-time relay timing and clock synchronization time control delay 24H timing 5 time periods\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003eProduct Highlights:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style=\"font-size:26;\"\u003eWide voltage power supply 5.0V ~ 60V;\u003c\/span\u003e \u003cbr\u003e\u003cspan style=\"font-size:26;\"\u003eA mode can be set for multiple time periods, can reach 5 time periods; \u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size:26;\"\u003eWith a buzzer alarm function.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003eMode introduction:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style=\"font-size:26;\"\u003eOPE: relay closing time point, CLE: relay off time point \u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size:26;\"\u003eTime period: PE-1 ~ PE-5 5 time periods (OPE to CLE is a time period) \u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size:26;\"\u003e----: function shielding\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003eP-1: The relay closes or outputs pulses every day to the OPE time point, and the relay turns off or outputs pulses to the CLE time point.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003eP-2: set the day, to the OPE time point when the relay closed or output pulse, to the CLE time point when the relay disconnect \/ or output pulse\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003eP-3: set the date of the month, to the OPE time point when the relay closed or output pulse, to the CLE time point when the relay is off or output pulse\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003eP-4: Set the date 1 to date 2, start every day at the OPE time point, end to the CLE time point, relay action or output pulse\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003eP-5: As with P-4, only the month can not be set\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003eFirst, how to set the time?\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003eIn the time to run the interface, press the DOWN button for a while:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003eStep 1: Select the time period: PE-1 ~ PE-5 Press UP and DOWN to select;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003eStep 2: Press the SET key to select the mode: P-1 ~ P-5 (Set this time period to the corresponding mode) by pressing the UP and DOWN keys. (\"----\" means to block this time period)\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003eNote: Each time period can be repeated from the \"----\", P-1 ~ P-5 one of the optional; For example,you can let five time periods at the same time work in the P-1 mode, or let Time period 1 work in P-1 mode, time period 2 work in P-2 mode and so on.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003eStep 3: After the mode selection is finished, press the SET key to enter the time period setting interface, set the interface in the time period, press the SET key to switch the parameter, \"OPE\" start time point, \"CLE\" end point, \"dAE\" date information;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style=\"font-size:26;\"\u003eStep 4: After setting the parameters to exit the settings, press the SET button for 2 seconds to release, automatically check whether the parameter settings are legal, legal to save the parameters, return to the time to run the interface; if the parameter is wrong, \"ERR\" reminder (for example, stop time or Date \u0026lt;= start time or date), return to the parameter setting interface; \u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size:26;\"\u003eAdditional features: Each \"time period\" can be set individually\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003eIn the specific parameter setting interface (after the second step), press the STOP button to switch the output mode:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003eOUT1: Start time point turns on the relay, the end time is off the relay\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003eOUT2: Outputs 1S pulse to start or end time\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003eIn the specific parameter setting interface (after the second step), press the STOP button for a while to switch the ringing mode:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003eBLL0: Ring disable\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003eBLL1: Ring enable\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003eNote: When the bell rings, press any button to stop the ring\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style=\"font-size:26;\"\u003eSTOP key function expansion: \u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size:26;\"\u003eRelay enable mode:\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e1. ON: enable relay on;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style=\"font-size:26;\"\u003e2. OFF: Do not turn on the relay, it is always off; \u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size:26;\"\u003ePress the STOP button on the time display interface to switch between ON and OFF, the current status will flash, and then return to the main interface. (This function is the emergency stop function, press once to close the closed relay)\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003eAfter the relay is disabled, the product can be used as an alarm clock.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003eSleep mode:\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e1. C-P sleep mode: within five minutes, without any operation, the digital tube automatically shut down the display, the program normal operation;\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cspan style=\"font-size:26;\"\u003e2. O-d normal mode: digital tube is always open display; \u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size:26;\"\u003ePress the STOP button for a while after 2 seconds to release, to achieve C-P and O-d state of the switch, the current state will flash, and then return to the main interface.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:26;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"width:600px;\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sc5422f47fa2d4f1e8858bd46cc95d4d8u.jpg\" data-src=\"https:\/\/ae01.alicdn.com\/kf\/Sc5422f47fa2d4f1e8858bd46cc95d4d8u.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"width:600px;\" src=\"https:\/\/ae01.alicdn.com\/kf\/S36c32666a7fc481e8af31a02db35255fz.jpg\" data-src=\"https:\/\/ae01.alicdn.com\/kf\/S36c32666a7fc481e8af31a02db35255fz.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"width:600px;\" src=\"https:\/\/ae01.alicdn.com\/kf\/S0b8b34edfad04dc38913c1adb7b576f3m.jpg\" data-src=\"https:\/\/ae01.alicdn.com\/kf\/S0b8b34edfad04dc38913c1adb7b576f3m.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"width:600px;\" src=\"https:\/\/ae01.alicdn.com\/kf\/S9e5f5466177847b593696eeac9d0628bq.jpg\" data-src=\"https:\/\/ae01.alicdn.com\/kf\/S9e5f5466177847b593696eeac9d0628bq.jpg\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\r\n","brand":"Yoeruyo","offers":[{"title":"CN","offer_id":55428890984747,"sku":"200007763:201441035","price":21.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/5744\/8747\/files\/S2d2a3585c00d4576a465c089325c887ab.webp?v=1788584513","url":"https:\/\/yoeruyo.com\/products\/dc-5v-real-time-timing-delay-timer-relay-module-switch-control-clock-synchronization-multiple-mode-control-wiring-diagram","provider":"Yoeruyo","version":"1.0","type":"link"}