{"product_id":"dc-6-30v-timer-relay-programmable-delay-relay-module-cycle-timer-with-led-display-6v-9v-12v-24v-micro-usb-smart-home-controller","title":"DC 6-30V Timer Relay Programmable Delay Relay Module Cycle Timer with LED Display 6V 9V 12V 24V Micro USB Smart Home Controller","description":"\u003ch1\u003eSPECIFICATIONS\u003c\/h1\u003e\u003cp\u003e\u003cspan\u003eApplication\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eComputer\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eBrand Name\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNONE\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eCondition\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNew\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eHigh-concerned chemical\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003enone\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOrigin\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eMainland China\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003ePackage\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eSMD\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eType\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eModule\u003c\/span\u003e\u003c\/p\u003e\u003cdiv class=\"detailmodule_html\"\u003e\u003cdiv class=\"detail-desc-decorate-richtext\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp style=\"font-weight:bold;line-height:inherit;margin-bottom:0px;margin-top:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box\"\u003e\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003e1. Operating voltage: 6--30V\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003e2. Trigger Signal Source: High Level Trigger (3.0 V-24 V), signal ground and system ground are not common, which can increase anti-interference abilit\u003c\/span\u003e\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003esystem (short circuit can also connect with a ground common)\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003e3. Output Capacity: can control no more than DC 30V 5A AC or 220 V devices 5A\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003e4. Optocoupler Isolation: improve the anti-interference ability, after the parameter setting, it will memory forever\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003eWarning: Relay contact is passive and electricity production; 1 channel has the control function on \/ off\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003eOperation mode:\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003eP1: After triggered signal, power relay on time OP, then turn off; within the OP period following operation:\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003e1) P1.1: signal being triggered again is not effective\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003e2) P1.2: signal being triggered again, start time again\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003e3) P1.3: signal being triggered again, reset; disconnect relay, stop timing\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003eP2: giving the trigger signal, the time after shutdown relay CL power relay OP time; then timing, turn off the relay\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003eP3.1: give the trigger signal after the power relay on time OP, CL shutdown time relay; then operating cycle above cycle gaive signal again, shutdown relay stop timing; cycle times (LOP) can be set\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003eP3.2: after connecting. no need to trigger signal, power relay on time OP, CL shutdown time relay; then the operating cycle above timea cycle (LOP) can be set\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003eQ4: keeping the function of the signal; if there is no trigger signal, the time will be canceled, relay stay connected; when the signal disappears, timing OP turn off the relay; over time, if no signal again, the time is cleared\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003eTime interval:\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003e0.1 s (minimum) ~ 999 min (maximum) continuously adjustable\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003ehow to choose the time interval:\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003ein the selection of parameter set interface mode, and press the STOP button to select the time\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003exxx. if the decimal point is in some place, the time interval is s-1 999 s\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003exx. x is decimal place is ten, the time interval is 0.1 s 99.9 s-\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003ex. x. x is the decimal point are all on, the time interval is 1 min-999 min\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003eparameter Introduction: OP power over time, turn off time CL, LOP cycle times (1-999 times, \"---\" is unlimited cycle)\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003eHow to set the parameter:\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003e1. First make sure relay operation mode\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003e2. According to the operaiting relay mode, the main interface (power module will flash current operating mode; standard mode P1.1, then come intot main interface); long press SET key two seconds and then looen enter selection interface mode; by pressing UP, DOWN key to choose the mode setting\u003c\/span\u003e\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003e(P1.1 ~ P4)\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003e3. After selecting the mode, press short SET to set the corresponding parameter, then the parameter you want to set will flash\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003e(OP power in time; CL power off time; LOP cycle times, \"---\" is unlimited cycle ); by UP, DOWN to set the parameter value, support long press\u003c\/span\u003e\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003e(increase or decrease quickly) and press slightly (increase or decrease of 1 unit); after setting the parameter value by short press the STOP key to choose decimal place; choose the time interval (corresponding time interval is 0.1 s-999 min); Short press SET to set the current mode next parameter, the process is the same as above\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003e4. After the setting mode parameter, press and hold the SET button then hold the current configuration mode will flash, then go back to the main interface; define success parameter\u003c\/span\u003e\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003emain interface: when the relay does not work, it will show \"000\" (no decimal point); the operating state relay, the screen has a decimal point\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003eMode Select Interface: press and hold the SET key to enter; after setting, long press the SET button back on main interface\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003eExpansion Function Key STOP:\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003eActivate Relay mode:\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003e1. NO: PO in power over time, relay can be connected\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003e2. OFF: relay is not allowed to connect, when in the off state\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003ein short main interface press the STOP key to achieve turn ON and OFF, current state will flash; then back to the main interface\u003c\/span\u003e\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003e(this function is a function of sudden stop, 1 key to turn off the relay)\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003eSleep Mode:\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003eC-P Sleep mode: within 5 minutes, no operation; nixie tube will close auto display, and a function program well\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003eThe d-Normal Mode: nixie tube show ever\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003eNote: Press and hold STOP button for 2 seconds can achieve change from C-P to O-d; Current state will flash and then return to the main interface\u003c\/span\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cspan style='font-size:18px;font-family:\"Times New Roman\"'\u003eSize: 6.3*3.8*1.5cm\/2.48\"*1.50\"*0.59\"\u003cimg cke-id=\"img58\" referrerpolicy=\"no-referrer\" src=\"https:\/\/ae-pic-a1.aliexpress-media.com\/kf\/Sf3984a5723ef4475852bd85ff3eeffadc.jpg?width=1000\u0026amp;height=595\u0026amp;hash=1595\"\u003e\u003cimg cke-id=\"img59\" referrerpolicy=\"no-referrer\" src=\"https:\/\/ae-pic-a1.aliexpress-media.com\/kf\/S44f0bcbee7b04bffa2b6a20c74a5f587I.jpg?width=1000\u0026amp;height=529\u0026amp;hash=1529\"\u003e\u003cimg cke-id=\"img60\" referrerpolicy=\"no-referrer\" src=\"https:\/\/ae-pic-a1.aliexpress-media.com\/kf\/Sad8bea7d1d324856a4dbabcdb5f7f86aR.jpg?width=1000\u0026amp;height=613\u0026amp;hash=1613\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\r\n","brand":"Yoeruyo","offers":[{"title":"TYPE-C","offer_id":55428889018667,"sku":"14:350852#TYPE-C","price":7.92,"currency_code":"USD","in_stock":true},{"title":"MICRO","offer_id":55428889051435,"sku":"14:1202#MICRO","price":7.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/5744\/8747\/files\/Scb47e675018642cbbaa3a8727b5a99bee.webp?v=1788584505","url":"https:\/\/yoeruyo.com\/products\/dc-6-30v-timer-relay-programmable-delay-relay-module-cycle-timer-with-led-display-6v-9v-12v-24v-micro-usb-smart-home-controller","provider":"Yoeruyo","version":"1.0","type":"link"}