{"product_id":"dc-9v-12v-24v-12a-voltage-detection-module-relay-charge-and-discharge-monitoring-module-output-voltage-detection-range-0-99-9v","title":"DC 9V\/12V\/24V 12A Voltage Detection Module Relay Charge and Discharge Monitoring Module Output Voltage Detection Range 0-99.9V","description":"\u003ch1\u003eSPECIFICATIONS\u003c\/h1\u003e\u003cp\u003e\u003cspan\u003eBrand Name\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNONE\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eCertification\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNONE\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eEU LVD Voltage\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eLow voltage: Below 50Vac or 75Vdc\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eHigh-concerned chemical\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003enone\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOrigin\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eMainland China\u003c\/span\u003e\u003c\/p\u003e\u003cdiv class=\"detailmodule_html\"\u003e\u003cdiv class=\"detail-desc-decorate-richtext\"\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size:20px\"\u003eDC 9V\/12V\/24V 12A Voltage Detection Module Relay Charge and Discharge Monitoring Module Output Voltage Detection Range 0-99.9V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:19px\"\u003eFeatures:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003ePowerful function, the detection range is DC 0-99.9V, and the minimum adjustment is 0.1V\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003echarging protection, discharge protection\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003eOvervoltage protection, undervoltage protection\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003eFixed-point pulse, stable performance\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003eCharge and discharge control, a variety of power supply voltage optional 5V\/12V\/24V\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:19px\"\u003eSpecifications:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003eDetection voltage range: 0-99.9V (minimum 0.1V adjustment)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003eWorking voltage: DC 9V\/12V\/24V optional\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003eThe maximum current of the relay contact: 12A (please leave a margin for use)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003eProduct size: 56mm*44mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:19px\"\u003eOperation introduction:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003e1. In the non-setting state, short press the SET button, and the cycle display: working mode -\u0026gt; lower limit voltage -\u0026gt; upper limit voltage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003e2. In the non-setting state, press the Changan SET key for 2 seconds to enter the parameter setting state; the display shows F01, press the +- key to select the parameter to be set, F01 (upper limit voltage), F02 (lower limit voltage), F03 working mode, F04 voltage calibration value.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003e3. After selecting the parameters to be set, short press the SET button to enter the parameter setting state, press the +- button to adjust, when the lower limit voltage is greater than or equal to the upper limit voltage, the display will display Err for 1 second to prompt the user. When the lower limit voltage is equal to the upper limit voltage, the relay output function is turned off.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003e4. After setting the parameter value, short press the SET key to return to the parameter list.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003e5. After setting the parameters, press and hold SET for 2 seconds to exit and save the parameters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003e6. In the non-setting state, press and hold the SET and + keys for 2 seconds at the same time to restore the factory settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003e7 Long press - turn off or turn on the digital tube display energy saving mode\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:19px\"\u003eDetailed settings:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003eF03 working mode non-setting state\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003eLong press SET to select F03 working mode selection, + and - to select the desired function, then long press SET to save and exit\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003ePlease note that before setting this parameter, please set the upper limit voltage and lower limit voltage as required\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003eH-1, Charging monitoring When the monitoring voltage is lower than the lower limit voltage, the relay pulls in, and when it is higher than the upper limit voltage, it disconnects.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003eH-2, Discharge monitoring When the monitoring voltage is higher than the upper limit voltage, the relay pulls in, and when it is lower than the lower limit voltage, it disconnects.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003eH-3 Pull-in outside the interval When the monitoring voltage is between the upper limit voltage and the lower limit voltage, the relay is disconnected, and the relay is closed in other states\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003eH-4 Pick-up in the interval When the monitoring voltage is between the upper limit voltage and the lower limit voltage, the relay picks up, and the other state relays are disconnected\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003eH-5 Fixed-point monitoring When the monitoring voltage is higher than the lower limit voltage, the relay is closed, and the relay is disconnected when it is lower than the lower limit voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003eH-6 Fixed-point self-locking monitoring When the monitoring voltage is higher than the lower limit voltage, the relay will pick up and keep picking up until manual intervention or power failure\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003eH-7 Fixed-point pulse monitoring When monitoring each time is equal to the lower limit voltage (±0.1V), the relay outputs a jog signal\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003eF04 Calibration mode Long press the SET key to enter in the non-setting state, +- to select\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003eThe default is 0 error, if you need to set the adjustment on demand,\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003eFor example, the actual input voltage is 12.5v, and the module displays 12.4V. At this time, you can correct and set the error to 0.1V, that is, 12.4+0.1=12.5\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003eFor example, the actual input voltage is 12.5v, and the module displays 12.6V. At this time, you can correct and set the error to -0.1V, that is, 12.6-0.1=12.5\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:19px\"\u003eNote:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"white-space:normal\"\u003e\u003cspan style=\"font-size:19px\"\u003e1. Due to the light and screen difference, the item's color may be slightly different from the pictures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"white-space:normal\"\u003e\u003cspan style=\"font-size:19px\"\u003e2. Please allow 1-3cm differences due to manual measurement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"white-space:normal\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp style=\"white-space:normal\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:19px\"\u003ePackage includes:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"white-space:normal\"\u003e\u003cspan style=\"font-size:19px\"\u003e1x Voltage Detection Module\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cspan style=\"font-size:19px\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"max-width:100%\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sd73eccdc9f0a47908af09f366cb1f44aL.jpg\" slate-data-type=\"image\"\u003e\u003cspan\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cimg style=\"max-width:100%\" src=\"https:\/\/ae01.alicdn.com\/kf\/S682cd70b1a8e4d7b8aeb7bc6712d93aar.jpg\" slate-data-type=\"image\"\u003e\u003cspan\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cimg style=\"max-width:100%\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sb2240278bea84ecc91f7954c9f7901acz.jpg\" slate-data-type=\"image\"\u003e\u003cspan\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cimg style=\"max-width:100%\" src=\"https:\/\/ae01.alicdn.com\/kf\/S21128fb803704d4fb9d03a8205117709J.jpg\" slate-data-type=\"image\"\u003e\u003cspan\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cimg style=\"max-width:100%\" src=\"https:\/\/ae01.alicdn.com\/kf\/S2c7ae0dec8454df0a22af3566000e159E.jpg\" slate-data-type=\"image\"\u003e\u003cspan\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cimg style=\"max-width:100%\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sdbd7d02862f443de8d27edb02deb3791O.jpg\" slate-data-type=\"image\"\u003e\u003cspan\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cimg style=\"max-width:100%\" src=\"https:\/\/ae01.alicdn.com\/kf\/S88aa773483514686869c424074bd375eE.jpg\" slate-data-type=\"image\"\u003e\u003cspan\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cimg style=\"max-width:100%\" src=\"https:\/\/ae01.alicdn.com\/kf\/S6fe351dbae2e4ebfbcf9dd6addca3767p.jpg\" slate-data-type=\"image\"\u003e\u003cspan\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cimg style=\"max-width:100%\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sa9fa5312135d487298cd06adaa650e5cH.jpg\" slate-data-type=\"image\"\u003e\u003cspan\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cimg style=\"max-width:100%\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sf8f335e914c3424980c51e3b94d01bf72.jpg\" slate-data-type=\"image\"\u003e\u003cspan\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cimg style=\"max-width:100%\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sef5941bdd0bd4a48a87bb95c060553e2D.jpg\" slate-data-type=\"image\"\u003e\u003cspan\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cimg style=\"max-width:100%\" src=\"https:\/\/ae01.alicdn.com\/kf\/S7d96323f6c7f448caa024ebb1e15ce1e7.jpg\" slate-data-type=\"image\"\u003e\u003cspan\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Yoeruyo","offers":[{"title":"9V","offer_id":55428740579627,"sku":"5:144170022#9V","price":53.46,"currency_code":"USD","in_stock":true},{"title":"12V","offer_id":55428740612395,"sku":"5:200004763#12V","price":53.46,"currency_code":"USD","in_stock":true},{"title":"24V","offer_id":55428740645163,"sku":"5:200004182#24V","price":53.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/5744\/8747\/files\/S6fe351dbae2e4ebfbcf9dd6addca3767p.webp?v=1788583487","url":"https:\/\/yoeruyo.com\/products\/dc-9v-12v-24v-12a-voltage-detection-module-relay-charge-and-discharge-monitoring-module-output-voltage-detection-range-0-99-9v","provider":"Yoeruyo","version":"1.0","type":"link"}