{"product_id":"dc12v-voltage-detection-module-relay-switch-charging-discharge-monitoring-protection-power-supply-accessories","title":"DC12V Voltage Detection Module Relay Switch Charging Discharge Monitoring Protection Power Supply Accessories","description":"\u003ch1\u003eSPECIFICATIONS\u003c\/h1\u003e\u003cp\u003e\u003cspan\u003eBrand Name\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eAideepen\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eCertification\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNONE\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eChoice\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eyes\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eCondition\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNew\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eContact Load\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eLow Power\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eDropship\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eSupport\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eKey Word\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eRelay Switch\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eModel Number\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eDC12V Voltage Detection Module Relay\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOrigin\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eMainland China\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003ePower Source\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eDC\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eProtect Feature\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eSealed\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eTheory\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eVoltage relay\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eType\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eRelay\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eUse\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eGeneral Purpose\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eVoltage\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e12V\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eis_customized\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eYes\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003esemi_Choice\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eyes\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"background-color:rgb(252, 196, 0);font-size:24px;font-family:arial, helvetica, sans-serif\"\u003e\u003ci\u003eDC12V Voltage Detection Module Relay Switch Charging Discharge Monitoring Protection Power Supply Accessories\u003c\/i\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg width=\"944\" height=\"283\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sed323aa25e274850b7ba84389d0b44b8A.jpg\" slate-data-type=\"image\"\u003e\u003cimg width=\"944\" height=\"283\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sfbd8f114b4f94f2b8aff5174ea419051f.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg width=\"944\" height=\"315\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sbf0ec15d87f147c2bf351510d1e4c66aP.jpg\" slate-data-type=\"image\"\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/S0d9857430bd84d54b1151bc5b929963cF.png\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003eFeatures\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003e1. Detection voltage range: 0-99.9V, minimum 0.1V start adjustment\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003e2. Charge protection, discharge protection\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003e3. Overvoltage protection, undervoltage protection\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003e4. Fixed-point pulse, stable performance\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003e5. Charge and discharge control, stable performance\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003eProduct parameters\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003eVoltage: DC12V\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003eMaximum current of relay contacts: 12A\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003eDetection voltage range: 0-99.9V\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003eParameter setting instructions\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003ePower on shows that the voltage is entered into the standby state, first set two basic parameters, the lower limit voltage V1 and the upper limit voltage V2\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003e1. Press the setting key once to display \"F1\" flashing\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003e2. Press the set button for the second time to display the default value of V1, \"XX.X\" flashes, press the \"plus\" button or the \"minus\" button to adjust the lower limit parameter V1\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003e3. Press the setting button for the third time to display the default V2 value \"XX.X\" flashing, press the \"plus\" button or \"minus\" button to adjust the upper limit parameter V2 (at this time, if the parameter of V1 is greater than V2, it will be displayed. \"ERR\" error prompt , the parameters need to be changed, it is normal to keep V1 smaller than V2)\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003e4. Press the SET button for the fourth time, the parameter will remain permanently and exit\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003e5. In standby mode, press the \"minus\" button for 3 seconds to turn off the display, and press it for 3 seconds to turn on the display. Designed for Low Power Consumption\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003eFunction Description\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003e1. F-1 charging monitoring: When the measured voltage is lower than the voltage V1, the relay is closed, and the voltage is higher than V2, the relay is disconnected\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003e2. F-2: Discharge monitoring: When the measured voltage is higher than the voltage V2, the relay is closed, and the voltage is lower than V1, the relay is disconnected\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003e3.F-3: pull-in outside the interval: when the measured voltage is introduced, the relay is disconnected between V1 and V2, and the relay pulls-in in other states\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003e4.F-4: Pick-up in the interval: When the measured voltage is introduced between V1 and V2, the relay picks up and other state relays are disconnected\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003e5.F-5: Fixed-point monitoring: When the measured voltage is higher than V1, the relay is closed, and when it is lower than V1, the relay is disconnected\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003e6.F-6: Fixed-point self-locking monitoring: When the measured voltage is higher than V1, the relay will pick up and keep picking up until the power is manually cut off\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003e7.F-7: Fixed-point pulse monitoring: when the measured voltage is equal to V1 (floating 0.1V up and down) the relay outputs a jog signal\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003e8.F-8: New function, voltage error correction, range ±5.0V.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003eSetting method supplement\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003eAfter F-1 is set, the parameters of other functions use the parameters set by F-1 after setting. After pressing the setting key, F-1 flashes, then press + or - to adjust the function number, and after adjusting to a certain function number, press the setting key and it will be OK. After pressing the setting key, F-1 flashes, then press + or - to adjust the function number, and after adjusting to a certain function number, press the setting key and it will be OK.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003ePackage list:\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"font-size:24px;font-family:arial, helvetica, sans-serif\"\u003eRelay module 1\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/S5a53b910e1524fb0a916b230060237735.png\" slate-data-type=\"image\"\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/Sbaa9aa36662748388b579cd35b9273e13.jpg\" slate-data-type=\"image\"\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/Sba76d5e396fd4091845cc314830d65205.jpg\" slate-data-type=\"image\"\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/S36bcaf850df54a2e9c5ee3e3c53d70f9N.jpg\" slate-data-type=\"image\"\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/S92d24c7c13f44d5f930c28445b6da420t.jpg\" slate-data-type=\"image\"\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/Scedf1407dc82494c962a72226b52d578P.jpg\" slate-data-type=\"image\"\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/Sfcf21517d6ea42e9a0d60ab4d449c08eN.jpg\" slate-data-type=\"image\"\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/S40ac237fac9741ef9f17c8b48bb417239.jpg\" slate-data-type=\"image\"\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/S2234c8c9e35a43d1ac4a8f412adeb487T.jpg\" slate-data-type=\"image\"\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/S026da309886e4719a93be0a3d41f730bt.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e","brand":"Yoeruyo","offers":[{"title":"Largest","offer_id":55428773708075,"sku":"5:144170022","price":22.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/5744\/8747\/files\/A7f0530bbde37415d867518cf0fd7cef1O.webp?v=1788583637","url":"https:\/\/yoeruyo.com\/products\/dc12v-voltage-detection-module-relay-switch-charging-discharge-monitoring-protection-power-supply-accessories","provider":"Yoeruyo","version":"1.0","type":"link"}