{"product_id":"hart-to-modbus-hart-protocol-converter-hart-to-rs485-to-232-sm100-b","title":"HART to MODBUS HART protocol converter HART to RS485 to 232  SM100-B","description":"\u003ch1\u003eSPECIFICATIONS\u003c\/h1\u003e\u003cp\u003e\u003cspan\u003eBrand Name\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNONE\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eHigh-concerned chemical\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003enone\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOrigin\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eMainland China\u003c\/span\u003e\u003c\/p\u003e\u003cdiv class=\"detailmodule_html\"\u003e\u003cdiv class=\"detail-desc-decorate-richtext\"\u003e\n\u003cdiv\u003e\n \u003cdiv\u003e\n  \u003cp\u003eSM100-B RS485 port: \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003eSM100-B (RS485 interface)\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp\u003eSM100-A RS232 port: SM100-A (RS232 interface)\u003c\/p\u003e\n  \u003cp\u003eType 3:SM100-A+B (RS232+RS485 interface)\u003c\/p\u003e\n  \u003cp\u003eType 4:SM100-B+B(double RS485)\u003c\/p\u003e\n  \u003cp\u003eType 5:SM100-A+D(RS232+built-in 24V)\u003c\/p\u003e\n  \u003cp\u003eType 6:SM100-B+D(RS485+built-in24V)\u003c\/p\u003e\n  \u003cp\u003eType 7:SM100-B+B+D(double RS485+ built-in 24V)\u003c\/p\u003e\n  \u003cp\u003eType 8:SM100-A+B+D(232+485+built-in 24V)\u003c\/p\u003e\n  \u003cp\u003e\u003cimg style=\"max-width:750px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S59934066686a4a0e8444abb70c96441bd.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n  \u003cp\u003e\u003cimg style=\"max-width:750px\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sf84aa504ee0c49f8b68e0f78f7f126aef.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n  \u003cp\u003e\u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003eSM100 Series HART intelligent converter is developed by using ARM microprocessor, HART protocol modulation and demodulation chip and combining a lot of practical experience. Designed according to the requirements of industrial products, with high reliability and stability. The intelligent converter is equipped with standard RS232 interface and RS485 interface, which can transmit data transparently with intelligent instrument with HART protocol or read data using MODBUS_RTU protocol to ensure real-time transmission of data. The HART protocol USES the Bell202 frequency shift keying (FSK) standard to overlay modulated digital signals on top of the 4-20mA, allowing bidirectional data communication without interfering with the 4-20mA analogue signal. SM100 series intelligent converter is an intelligent converter for bidirectional modulation and demodulation of digital and analog signals.\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp\u003e\u003cimg style=\"max-width:750px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S1a497c204e51427f909945b85272c23fq.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n  \u003cdiv style=\"text-align:left\" align=\"left\"\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003eProduct features\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e1. Equipped with standard RS232 and RS485 communication interfaces, parameters can be configured, communication baud rate and parity bit can be changed, which has nothing to do with the 1200 communication speed on HART bus, so as to improve the running speed of the whole system.\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e2. Industrial common module shell is adopted for easy installation and debugging.\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e3. Equipped with special configuration software, the SM100 series intelligent converter can communicate data with HART protocol intelligent instrument and configure intelligent converter parameters\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e4. Support for the standard MODBUS_RTU protocol.\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e5. Support simultaneous connection of multiple HART protocol intelligent instruments.\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cp\u003e\u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e6. Supports a variety of special HART protocol intelligent instruments, and can customize the HART instrument to read special HART protocol instructions.\u003c\/span\u003e\u003c\/p\u003e\n   \u003cp\u003e\u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003eTechnical parameters of SM100 series products\u003c\/span\u003e\u003c\/p\u003e\n   \u003cdiv\u003e\n     \n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e1. Power supply: DC12 -- 24V: The ripple of the power supply shall not be greater than 200mV, and the current shall be provided with 100mA.\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e2. Physical size: length 134mm * width 71mm * height 43mm.\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e3. Operating temperature: -20℃ -- 80℃.\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e4. Relative humidity: 10%-80%.\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cp\u003e\u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e5. Product weight: 0.25Kg\u003c\/span\u003e\u003c\/p\u003e\n   \u003cp\u003e\u003cspan style='background-color:rgb(247, 248, 250);font-size:14px;font-family:arial, \"microsoft yahei\", \"\\\\5fae\", \"\\\\5b8b\", \"malgun gothic\", meiryo, sans-serif'\u003eThe difference between transparent protocol and MODBus-RTU\u003c\/span\u003e\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cp\u003e\u003cimg style=\"max-width:750px\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sc8f7dabedb7e4f3db7d6ae6445e351aa3.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n  \u003cp\u003e\u003cimg style=\"max-width:750px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S1d3d4ed1029440a6bb082c1caaa7b5eei.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n  \u003cp\u003e\u003cimg style=\"max-width:750px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S4d2f0c9dbe3242a8abe9772724e45876L.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n  \u003cp\u003e\u003cspan style='background-color:rgb(247, 248, 250);font-size:14px;font-family:arial, \"microsoft yahei\", \"\\\\5fae\", \"\\\\5b8b\", \"malgun gothic\", meiryo, sans-serif'\u003eHart-modbus converter is applied in data acquisition of MODBUS-RTU\u003c\/span\u003e\u003c\/p\u003e\n  \u003cp\u003e\u003cimg style=\"max-width:750px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S34c16703ac7445a7b401da8b1fde2a23R.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n  \u003cp\u003eApplication of Hart-Modbus converter in DCS(PLC) control system\u003c\/p\u003e\n  \u003cp\u003e\u003cimg style=\"max-width:750px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S2da39ae0b19c439fab3c204b4d048593e.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n  \u003cdiv style=\"text-align:left\" align=\"left\"\u003e\n   \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003eActual field test application diagram\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"text-align:left\" align=\"left\"\u003e\n   \u003cimg style=\"max-width:750px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S0a3bc11a3a4242e59941ccd73e183786s.jpg\" slate-data-type=\"image\"\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"text-align:left\" align=\"left\"\u003e\n   \u003cspan style=\"font-size:14px\"\u003e\u003cstrong\u003eSM100-A(B) HART \u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003econverter can communicate instruments (all field tests passed)\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv\u003e\n   \u003cdiv\u003e\n    \u003cdiv style=\"text-align:left\" align=\"left\"\u003e\n     \u003cdiv style=\"text-align:left\" align=\"left\"\u003e\n      \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003eSM100 series intelligent converter external interface and indicator light function\u003c\/span\u003e\n     \u003c\/div\u003e\n     \u003cdiv style=\"text-align:left\" align=\"left\"\u003e\u003c\/div\u003e\n     \u003cdiv style=\"text-align:left\" align=\"left\"\u003e\n      \u003cdiv\u003e\n       \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e1. Detailed explanation of external wiring terminals and indicator lights (as shown in the figure)\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cdiv\u003e\n       \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e● Power interface terminal: POW(power positive) GND(power negative).\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cdiv\u003e\n       \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e● ARS485 interface A Terminal: ARS485D+ ARS485D-.\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cdiv\u003e\n       \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e● BRS485 interface B terminal: standby.\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cdiv\u003e\n       \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e● RS232 Communication interface terminal: RS232TX RS232RX.\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cp\u003e\u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e● HART instrument interface terminal: four groups of HART instrument communication interfaces (Loop1-loop4).\u003c\/span\u003e\u003c\/p\u003e\n      \u003cp\u003e\u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e2. Indicator light instructions\u003c\/span\u003e\u003c\/p\u003e\n      \u003cp\u003e\u003cimg style=\"max-width:750px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S18d6a224710840729c913fce4617c0adO.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n     \u003c\/div\u003e\n    \u003c\/div\u003e\n   \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv\u003e\n   \u003cdiv\u003e\n    \u003cdiv\u003e\n     \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e● POW power indicator light: always on after power on.\u003c\/span\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e● RS485 communication indicator light: flashes when RS485A serial port data exchange occurs.\u003c\/span\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e● RS232 communication indicator light: flashes when RS232 serial port data exchange.\u003c\/span\u003e\n    \u003c\/div\u003e\n    \u003cp\u003e\u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e● HART communication indicator light: flashes when data exchange between HART converter and HART instrument.\u003c\/span\u003e\u003c\/p\u003e\n    \u003cp\u003e\u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003eSM100 series intelligent converter and HART protocol intelligent instrument wiring\u003c\/span\u003e\u003c\/p\u003e\n    \u003cp\u003e\u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e1. Wiring diagram of HART protocol intelligent instrument with two wires\u003c\/span\u003e\u003c\/p\u003e\n   \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"text-align:left\" align=\"left\"\u003e\n   \u003cdiv style=\"text-align:left\" align=\"left\"\u003e\n    \u003cimg style=\"max-width:750px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S908c90e62b354eb09b742524e698699cs.jpg\" slate-data-type=\"image\"\u003e \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e2. Wiring diagram of HART protocol intelligent instrument with four-wire system\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cp\u003e\u003cimg style=\"max-width:750px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S1ae1e680cdda44179b2e3ae49d2627d6D.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e3.HART converter and two-wire and four-wire HART protocol intelligent instrument use wiring diagram simultaneously\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cp\u003e\u003cimg style=\"max-width:750px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S092faa485dfa4ac5bb5636a8b3852fe7P.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e4. Wiring diagram of intelligent instrument between DC24V and two-wire HART protocol built in HART converter\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cp\u003e\u003cimg style=\"max-width:750px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S2a1e84ff539f46c7a0dde4baa768651f3.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n   \u003cp\u003e\u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e5. Differences between two-wire HART instrument and four-wire HART Instrument\u003c\/span\u003e\u003c\/p\u003e\n   \u003cp\u003e\u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e● The power line of the four-wire HART instrument is separated from the 4-20mA input and output lines for separate power supply.\u003c\/span\u003e\u003c\/p\u003e\n   \u003cdiv\u003e\n     \n   \u003c\/div\u003e\n   \u003cp\u003e\u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e● The power line of the two-wire HART instrument is Shared with the 4-20mA input and output lines\u003c\/span\u003e\u003c\/p\u003e\n   \u003cdiv style=\"text-align:left\" align=\"left\"\u003e\u003c\/div\u003e\n   \u003cdiv style=\"text-align:left\" align=\"left\"\u003e\u003c\/div\u003e\n   \u003cdiv style=\"text-align:left\" align=\"left\"\u003e\n    \u003cdiv\u003e\n     \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003eDetails of SM100 series configuration software\u003c\/span\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e1. System parameter interface function introduction\u003c\/span\u003e \u003cimg style=\"max-width:750px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S2e05b2f1fedc44c0986f1a6af5216eebn.jpg\" slate-data-type=\"image\"\u003e\n    \u003c\/div\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e2. Transparent transmission interface function introduction\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv style=\"text-align:left\" align=\"left\"\u003e\n    \u003cimg style=\"max-width:750px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S46a4b964f70b4f2eb1aa65a1ea9b3d5dA.jpg\" slate-data-type=\"image\"\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e3. Introduction of interface functions of General HART Agreement\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv style=\"text-align:left\" align=\"left\"\u003e\n    \u003cimg style=\"max-width:750px\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sb950c8c106434cd19d6cc2163b3c84f8m.jpg\" slate-data-type=\"image\"\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e4. Introduction of interface functions of special HART coordinator\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv style=\"text-align:left\" align=\"left\"\u003e\n    \u003cimg style=\"max-width:750px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S98ef1ff9778048d98becae12be4357a1z.jpg\" slate-data-type=\"image\"\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e5. Introduce the interface functions of HART Agreement\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv style=\"text-align:left\" align=\"left\"\u003e\n    \u003cimg style=\"max-width:750px\" src=\"https:\/\/ae01.alicdn.com\/kf\/Scb4965e21a2b4f98bb08a5a4d63b441fU.jpg\" slate-data-type=\"image\"\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003e6. Read data with ModScan32 test software\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv style=\"text-align:left\" align=\"left\"\u003e\n    \u003cimg style=\"max-width:750px\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sfd0800a3281b4795bc113a94e461aeaeD.jpg\" slate-data-type=\"image\"\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cspan style=\"color:rgb(46, 48, 51);font-size:14px\"\u003eData register address\u003c\/span\u003e\n   \u003c\/div\u003e\n   \u003cdiv style=\"text-align:left\" align=\"left\"\u003e\n    \u003cimg style=\"max-width:750px\" src=\"https:\/\/ae01.alicdn.com\/kf\/S2f828828b7364530837b9fd8f5915721f.jpg\" slate-data-type=\"image\"\u003e\n   \u003c\/div\u003e\n  \u003c\/div\u003e\n \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\r\n","brand":"Yoeruyo","offers":[{"title":"SM100-B RS485 port","offer_id":55514532086059,"sku":"14:201637806#SM100-B RS485 port","price":483.2,"currency_code":"USD","in_stock":true},{"title":"SM100-A RS232 port","offer_id":55514532118827,"sku":"14:200004889#SM100-A RS232 port","price":483.2,"currency_code":"USD","in_stock":true},{"title":"Type 3","offer_id":55514532151595,"sku":"14:200004890#Type 3","price":578.36,"currency_code":"USD","in_stock":true},{"title":"Type 4","offer_id":55514532184363,"sku":"14:200004891#Type 4","price":578.36,"currency_code":"USD","in_stock":true},{"title":"Type 5","offer_id":55514532217131,"sku":"14:200003699#Type 5","price":625.72,"currency_code":"USD","in_stock":true},{"title":"Type 6","offer_id":55514532249899,"sku":"14:200002130#Type 6","price":625.72,"currency_code":"USD","in_stock":true},{"title":"Type 7","offer_id":55514532282667,"sku":"14:365458#Type 7","price":625.72,"currency_code":"USD","in_stock":true},{"title":"Type 8","offer_id":55514532315435,"sku":"14:350850#Type 8","price":625.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/5744\/8747\/files\/Sd32a5e2fa2c94e4a90bef458f236964eH.webp?v=1789011810","url":"https:\/\/yoeruyo.com\/products\/hart-to-modbus-hart-protocol-converter-hart-to-rs485-to-232-sm100-b","provider":"Yoeruyo","version":"1.0","type":"link"}