{"product_id":"network-lightning-protector-spd-monitor-camera-surge-protector-rj45-gigabit-ethernet-protection-device-arrester","title":"Network Lightning Protector SPD Monitor Camera Surge Protector RJ45 Gigabit Ethernet Protection Device Arrester","description":"\u003ch1\u003eSPECIFICATIONS\u003c\/h1\u003e\u003cp\u003e\u003cspan\u003eAssembly Required\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eno\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eBrand Name\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNONE\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eChoice\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eyes\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eHigh-concerned chemical\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003enone\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOrigin\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eMainland China\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eType\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eCable Adapter\u003c\/span\u003e\u003c\/p\u003e\u003cdiv class=\"detailmodule_html\"\u003e\u003cdiv class=\"detail-desc-decorate-richtext\"\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"font-size:16px\"\u003e\u003cspan style=\"font-family:verdana, geneva, sans-serif\"\u003eScope of application:\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003e Suitable for computer data interface or network interface, hub, network card, network switch, modem, fax, data communication, etc. The over-voltage protection of network system is protected from induced overvoltage, operating overvoltage and electrostatic discharge. Damage; multi-stage protection, large current capacity, low voltage limit, fast response time, low insertion loss, high transmission rate, etc.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003eWhy use a surge protector?\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003e       The destructive power of lightning is extremely large. It is not enough to rely solely on external lightning protection (lightning rods, etc.). Lightning waves indirectly or indirectly (through electromagnetic induction) invade electrical passages and metal passages (such as power lines, signal lines, antenna feeders and metals). Pipes, etc.). The resulting lightning overvoltage and surge voltage will cause great harm to electronic, electrical equipment, and information network systems. If the line is damaged, the equipment will be damaged and the system will be paralyzed, resulting in an incalculable loss.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003e       Rapidly changing lightning currents can induce high voltages on electrical loops and twin-wires that can damage the insulation of the system. Various operations of the power system can generate operating overvoltage on the power line; some electrical equipment switching operations, short circuit trips, etc. can generate overvoltage (surge voltage) higher than the normal working voltage in the power line, thereby causing damage to the electrical equipment. .\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:16px\"\u003e\u003cspan style=\"font-family:verdana, geneva, sans-serif\"\u003eTechnical Parameters:\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003eModel RJ45 network signal lightning arrester\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003eProtected object network signal\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003eRated working voltage Un: 5V\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003eMaximum continuous operating voltage Uc: 7.8V\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003eMaximum discharge current Imax (8\/20us): 10KA\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003eImpact limit voltage Up (10\/700\/ms): \u0026lt;20V\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003eInsertion loss: 0.1dB\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003eResponse time: ~1ns\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003eProtection pin: 1\/2\/3\/6\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003eMaximum transmission rate: 100MHz\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003eConnector form: RJ45\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003eOperating temperature range: -40 ° C ~ +85 ° C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003eAt room temperature: humidity 30%-90%\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003eShell protection rating: IP20\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003eInsulation resistance MΩ: ≥0.4\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003eNear-end crosstalk dB: ≥ 60 (PASS)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003eBandwidth FG: 100 M\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003eProtection line: single way\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"font-size:16px\"\u003e\u003cspan style=\"font-family:verdana, geneva, sans-serif\"\u003eInstallation instructions and precautions:\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003e1) Installed in series between the lines of the protected equipment, the interface connection must be reliable, and the surge protector has input (IN) and output (OUT) marks. The output is connected to the protected device and must not be connected. Otherwise, the lightning protector will be damaged when lightning strikes, and the equipment will not be effectively protected.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003e2) If the loss increases due to factors such as poor connection of the connector, reconnect or replace the protector.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003e3) Disconnect the equipment when installing the grounding wire to avoid damage to the equipment caused by strong current such as electric welding from the grounding end.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003e4) Before the surge protector string is connected to the protected device, the power must be turned off and the live operation is prohibited.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003e5) The grounding wire (PE) must be reliably connected to the ground of the surge protection system and the shortest length is required for optimum protection.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003e6) Users are not allowed to disassemble the fasteners in various parts of the protector to avoid damage and affect normal work.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003cspan style=\"font-size:16px\"\u003e\u003cspan style=\"font-family:verdana, geneva, sans-serif\"\u003eCheck of the protector:\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003e1\" Use the three-meter \"Ω × 1\" file to measure the corresponding input to the output resistance value of about 0 Ω, if the resistance is too large and abnormal, the protector should be replaced.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003e2\" Use the three-meter \"Ω × 10K\" file to measure the resistance of the wire to the outer casing, which is about 400kΩ; the resistance of the wire to the ground and the outer casing to the ground should be infinite. If the measured resistance does not match the above, the protector should be replaced.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\u003cspan style=\"font-size:18px;font-family:arial, helvetica, sans-serif\"\u003e3) The lightning protection device does not need special maintenance, such as being damaged by high voltage and lightning strikes. (When the LED indicator is off, it indicates that the lightning protection function has been lost.) When the system equipment fails, the lightning protection device can be removed to see if the equipment works normally. If it can be restored to normal, the lightning arrester is damaged and the protector should be replaced.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/S66391b9f563d467e8fb1574bb56a9094u.jpg\" slate-data-type=\"image\"\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/S3831e0089d014ed0bcf89361036e9f83E.jpg\" slate-data-type=\"image\"\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/Saa846bb013cf4d2882e0649dad91eea80.jpg\" slate-data-type=\"image\"\u003e\u003cimg src=\"https:\/\/ae01.alicdn.com\/kf\/S92cd8de3568c4afdb732aa62115d4a173.jpg\" slate-data-type=\"image\"\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Yoeruyo","offers":[{"title":"Default Title","offer_id":55650506047787,"sku":"\u003cnone\u003e","price":29.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/5744\/8747\/files\/S3831e0089d014ed0bcf89361036e9f83E.webp?v=1789886178","url":"https:\/\/yoeruyo.com\/products\/network-lightning-protector-spd-monitor-camera-surge-protector-rj45-gigabit-ethernet-protection-device-arrester","provider":"Yoeruyo","version":"1.0","type":"link"}