{"product_id":"one-relay-module-xy-j02-time-delay-power-cut-off-trigger-delay-cycle-timing-circuit-switch","title":"One Relay Module XY-J02 Time Delay Power Cut Off Trigger Delay Cycle Timing Circuit switch","description":"\u003ch1\u003eSPECIFICATIONS\u003c\/h1\u003e\u003cp\u003e\u003cspan\u003eApplication\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eComputer\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eBrand Name\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eSTJF\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eChoice\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eyes\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eCondition\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNew\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eDissipation Power\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e...\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eFunctions\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eElectronic Module\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eHigh-concerned chemical\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003enone\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e-40℃~+80℃\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOrigin\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eMainland China\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003ePackage\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eDIY Module\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eRange of application\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eSwitch And Sensor For Arduino STM\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eSupply Voltage\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e6-30v\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eType\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eModule\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003esemi_Choice\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eyes\u003c\/span\u003e\u003c\/p\u003e\u003cdiv class=\"detailmodule_html\"\u003e\u003cdiv class=\"detail-desc-decorate-richtext\"\u003e\u003cspan style=\"font-size:28px;\"\u003e \u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\" data-spm-anchor-id=\"a2g0o.detail.1000023.i0.7a6314a11QAQzQ\"\u003eOne way relay module, time delay power cut off, trigger delay cycle timer circuit switch.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003e0.1 second (min) ~999 min (max) continuous tunable\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eThis product is simple and easy to use, powerful, but please buyers in detail to see the operation instructions of this product, very practical products.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eModule highlights:\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003e1. wide voltage power supply (6~30V) supports micro USB 5.0V power supply, which is very convenient to use.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003e2. the interface is clear and simple, powerful, easy to understand, almost meet all your needs.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003e3., there is one button emergency stop function (STOP key), with reverse connection protection, reverse connection without burning.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003e4. increase the sleep mode and enable the operator to turn off the display automatically after 5 minutes without any operation.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003e5., you can set different parameters of OP, CL and LOP, which are independent of each other.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003e6. all set parameters automatically save the power.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eWork model:\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eAfter the P1: signal is triggered, the relay will lead to OP time and then disconnect; in OP time, the following operations are performed.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eP1.1: signal re - trigger invalid\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eP1.2: the signal triggers the time again\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eP1.3: the signal is triggered again, the relay is disconnected, and the timer is stopped.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eP-2: to trigger the signal, the relay disconnects the CL time, the relay conducts OP time, and after the timer is completed, the relay is disconnected.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eP3.1: after the trigger signal is triggered, the relay opens the time of OP, the relay disconnects the CL time, and then circulate the above action, the relay is given again the signal, the relay is disconnected and the timing is stopped; the cycle times (LOP) can be set;\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eP3.2: after power on, there is no need to trigger the signal, the relay can lead OP time, the relay disconnects CL time, circulate the above actions, and the number of cycles (LOP) can be set.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eP-4: if the signal has a trigger signal, the timing is zero, the relay is kept open; when the signal is disappearing, the relay is broken after the time of time OP; during the time of time, the signal is repeated and the time is zero;\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eProduct parameters:\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003e1: working voltage: 6--30V supports micro USB 5.0V power supply.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003e2: trigger signal source: high level triggering (3.0V - 24V) signal does not improve the system's anti-jamming capability with the system.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003e3: output capability: equipment that can control DC 30V 5A or less than 220v5A.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003e4: static current: 20mA working current: 50mA\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003e5: service life: greater than 100 thousand times; working temperature: -40 - 85 C; size: 6.2*3.8*1.7cm\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003e6: with optocoupler isolation, enhance anti-interference ability, industrial grade circuit boards, set parameters after power failure forever.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eMemory.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eSpecial attention: relay output is passive contact, uncharged output, to control the role of a circuit on and off.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eTime range\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003e0.1 second (min) ~999 min (max) continuous tunable\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eHow to choose the time range:\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eAfter setting the parameter values in the mode selection interface, select the time range by short pressing the STOP key.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eXXX. decimal point in bit, time range: 1 second ~999 sec.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eXX.X decimal point in ten places, time range: 0.1 seconds ~99.9 seconds.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eX.X.X. the decimal point is bright. The time range is 1 minutes ~999 minutes.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eFor example, if you want to set OP to 3.2 seconds, move the decimal point to ten bits, and the digital tube displays 3.2.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eParameter Description: OP lead time, CL disconnection time, LOP cycle number (1 to 999 times, \"---\" represents infinite cycle).\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eThese parameters are independent of each other, but each pattern shares these parameters, for example, in the P1.1 setting the pass time OP is 5 seconds, the user wants to switch to the P1.2 mode, then the OP will be 5 seconds when the corresponding parameters are set into the P1.2;\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eAt the main interface (display 000), short press SET button will display OP (CL, LOP) and the corresponding time XXX;\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eIf there is only OP (for example, mode P1.1, P1.2, P1.3) in the pattern, then the short SET key will only show OP and the corresponding time.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eIf there are OP, CL and LOP (for example, mode P3.1, P3.2) in the pattern, the short pressing of SET key will display OP and corresponding time, CL and corresponding time, LOP and corresponding times;\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eAfter setting up the mode, you can easily view the parameters set in the current mode by short pressing the SET key in the main interface, which is very convenient.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eHow to set parameters\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003e1. first, determine the working mode of the relay.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003e2. according to the working mode of the relay, when the main interface is on the main interface, it will flicker the current working mode (the default P1.1 mode), and then enter the main interface, and \"long press SET key\" into the mode selection interface after 2 seconds, and select the mode to set by short press UP and DOWN keys (P1.1~P-4).\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003e3. after selecting the mode to set up (for example, P3.2) set the corresponding parameters by the SET key, the parameters to be set will flicker (OP conduction time, CL break time, LOP cycle times (\"-\" for infinite cycle)), adjust the parameter values through UP, DOWN, support long press (fast increase or decrease) and short press ( Add or reduce 1 units); set a good parameter value, by short press STOP key to select the decimal point position, select the time range (the corresponding time 0.1 seconds ~999 minutes); short press SET key, set the next parameter of the current mode, the process is the same.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003e4. set the parameters of the selected mode, after the long press SET key 2 seconds loosened, the current set pattern will flicker, and then return to the main interface, setting the parameters successfully, very simple!\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eMain interface: relay does not work state display \"000\" (no decimal point), relay working state with decimal point, very clear!\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eMode selection interface: long press SET key to enter, after setting up, long press SET button to exit, return to the main interface, very simple!\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eSTOP key function extension:\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eRelay enabled mode:\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003e1. ON:OP conduction\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003e2. OFF: the relay is forbidden to turn on and is always closed.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eIn the main interface, press STOP button to achieve the switch between ON and OFF. The current state will blink and then return to the main interface. (this function is emergency stop function, one key disconnects closed relay).\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003eSleep pattern:\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003e1. C-L sleep mode: five minutes, no operation, digital tube automatic closing display, normal operation of the program;\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003e2. O-d normal mode: digital tube always opens and displays.\u003c\/h3\u003e\n\u003ch3 style=\"box-sizing:border-box;word-spacing:0px;text-transform:none;color:#222222;outline-width:0px;font-style:normal;outline-style:none;orphans:2;widows:2;letter-spacing:normal;outline-color:invert;text-indent:0px;-webkit-tap-highlight-color:transparent;font-variant-ligatures:normal;font-variant-caps:normal;-webkit-text-stroke-width:0px;text-decoration-thickness:initial;text-decoration-style:initial;text-decoration-color:initial;\"\u003ePress the STOP button for 2 seconds to loosen it and achieve the switch between C-L and O-d status. The current state will flicker and return to the main interface.\u003c\/h3\u003e\n\u003cp\u003e\u003cimg style=\"width:1000px;\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sbb440c17e9584df098008ae2001b4cc2b.jpg\" data-src=\"https:\/\/ae01.alicdn.com\/kf\/Sbb440c17e9584df098008ae2001b4cc2b.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"width:1000px;\" src=\"https:\/\/ae01.alicdn.com\/kf\/S0a5b9b1e930a441586f759f9caa77d8aX.jpg\" data-src=\"https:\/\/ae01.alicdn.com\/kf\/S0a5b9b1e930a441586f759f9caa77d8aX.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"width:1000px;\" src=\"https:\/\/ae01.alicdn.com\/kf\/S2179477ab887438289cdc76d0e3fa88eb.jpg\" data-src=\"https:\/\/ae01.alicdn.com\/kf\/S2179477ab887438289cdc76d0e3fa88eb.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"width:1000px;\" src=\"https:\/\/ae01.alicdn.com\/kf\/S473065b872cf45e3a99e442b6781f26aH.jpg\" data-src=\"https:\/\/ae01.alicdn.com\/kf\/S473065b872cf45e3a99e442b6781f26aH.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"width:1000px;\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sa068d19703a04b2ba6e48b5eba0e2e74Z.jpg\" data-src=\"https:\/\/ae01.alicdn.com\/kf\/Sa068d19703a04b2ba6e48b5eba0e2e74Z.jpg\"\u003e\u003c\/p\u003e\u003c\/span\u003e\u003c\/div\u003e\u003c\/div\u003e\r\n","brand":"Yoeruyo","offers":[{"title":"Default Title","offer_id":55428891017515,"sku":"\u003cnone\u003e","price":11.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/5744\/8747\/files\/Secd7dfe09a814501bdaad54b762c2763N.webp?v=1788584513","url":"https:\/\/yoeruyo.com\/products\/one-relay-module-xy-j02-time-delay-power-cut-off-trigger-delay-cycle-timing-circuit-switch","provider":"Yoeruyo","version":"1.0","type":"link"}