{"product_id":"samwha-dsp-avr-3s-xxa-3x380v-nuetral-adjustable-current-voltage-non-sync-relay-63a-80a-100a","title":"Samwha-Dsp AVR-3S-XXA 3x380V+Nuetral Adjustable Current \u0026 Voltage Non-sync Relay 63A,80A,100A","description":"\u003ch1\u003eSPECIFICATIONS\u003c\/h1\u003e\u003cp\u003e\u003cspan\u003eBrand Name\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003esamwhadsp\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eCertification\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eCE\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eContact Load\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eHigh Power\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eEU LVD Voltage\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eHigh voltage: Above 50Vac or 75Vdc\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eHigh-concerned chemical\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003enone\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eModel Number\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eAVR-3S\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOrigin\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eMainland China\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003ePower Source\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eAc\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eProtect Feature\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eSealed\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eUse\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eProtective\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eVoltage\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e380V\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eis_customized\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eYes\u003c\/span\u003e\u003c\/p\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003e-General-\u003c\/p\u003e\n\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eAVR Current \u0026amp; voltage protection relay is designed to protect devices with sensitive operating voltage \u0026amp; currentvalues from errorsthat may arise from mains voltage and Overload.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003e-Device Usage and Principle of Operation -\u003c\/p\u003e\n\u003cp style=\"font-weight:normal\"\u003eMake the connections of the device according to the connection type. Otherwise, the device may be damaged. Adjust the over-current andhigh \u0026amp; low voltage and settings of the device according to the coperating current and voltage values of the load you will use.\u003cbr\u003e\u003cbr\u003eOver-current Error state: If the current value is under the current set values (when the device is not in error), the current value risesabove the current set value, the device waits for the set error waiting time, then the device de-energizes the relay , the error led lurn on, the overload value displayed on the current display flashes throughout the error period.\u003cbr\u003e\u003cbr\u003eVoltage Error state: If the mains (input) voltage value is between the high and Low voltage set values (when the device is not in error), the mains (input) voltage value rises above the high voltage set value or under below the low voltage set value; the devicewaits for the set error waiting time, then the device de-energizes the relay, the error led lurn on, the mains linputl voltage value displayed on the voltage display flashes throughout the error period.\u003cbr\u003e\u003cbr\u003eExit the Over-current Error state: After eliminating the load over-current fault, Press twice the on\/off key to manual reset or cut off the power supply.\u003cbr\u003eNote_1: Manual reset is to avoid secondary damage to the system by automatically resetting the system without excluding over-current or short circuit.\u003cbr\u003e\u003cbr\u003eExit voltage error state: When the mains (input) voltage value returns to normal \/ when the reaches a value between thehigh and Low voltage set values the device waits for the set reset waiting time, then the device energizes the relay. the error led turns off, the out led turns on.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003e-Display and Buttons-\u003c\/p\u003e\n\u003cp style=\"color:rgb(0, 0, 0)\"\u003e1 - Over current setting knob\u003cbr\u003e\u003cbr\u003e2 - High voltage setting knob\u003cbr\u003e\u003cbr\u003e3 - Low voltage setting knob\u003cbr\u003e\u003cbr\u003e4 - Delay time setting knob\u003cbr\u003e\u003cbr\u003e5 - Reset time setting knob\u003cbr\u003e\u003cbr\u003e6 - Manual On\/Off Button:\u003cbr\u003eFor close the device output.In this state, the screen will display \"off\" and the device cannot be automatic reset. Press this button againto switch on the device intouse again (No failure premise).\u003cbr\u003e\u003cbr\u003e7 - Current Display\u003cbr\u003e1St Display Group: During normal operation,current value is displayed here, the screen lights up steadily when not in error state.the display flashesin case of error (over-current).\u003cbr\u003eDuring the programming process,the value of the relevant program is shown on the display (Over-current and high\/low volt, delay time.reset time setting values).\u003cbr\u003e\u003cbr\u003e8 - Voltage Display\u003cbr\u003e2St Display Group: During normal operation, the input voltage value is displayed here,the screen lights up steadily when not in error state.the display flashesin case of error(high or low voltage).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e9 - LEDs:\u003cbr\u003e L1:Light up when phase L1 output.\u003cbr\u003e\u003cbr\u003e L2:Light up when phase L2 output. \u003cbr\u003e\u003cbr\u003e L3:Light up when phase L3 output.\u003cbr\u003e\u003cbr\u003e A\u0026gt;:Light up when an over-current fault occurs.\u003cbr\u003e\u003cbr\u003e V\u0026gt;:Light up when an high voltage fault occurs.\u003cbr\u003e\u003cbr\u003e V\u0026lt;:Light up when an low voltage fault occurs.\u003cbr\u003e\u003cbr\u003e V\u0026lt;: Light up when an low voltage fault occurs.\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg style=\"margin-bottom:10px\" class=\"detail-desc-decorate-image\" width=\"452\" height=\"265\" src=\"https:\/\/ae01.alicdn.com\/kf\/S4516204a387243faad41d51f349aa7e8C.png\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003e-Working-\u003c\/p\u003e\n\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eMake the connections of the device according to the connection type.\u003cbr\u003e\u003cbr\u003eExample: Set the low voltage value (U\u0026lt;) to 160V. The high voltage value (U\u0026gt;) to 260V the delay time of (D-T) is 5 sec, and the reset of (R-T) is 10 sec.\u003cbr\u003e\u003cbr\u003eWhen the L1 to N is lower than 160V, after 5 seconds of D-T setting, L1 turn off the output. \u003cbr\u003eWhen the voltages L1to N return to the normal range, L1turn on the output after 10 seconds of R-T setting.\u003cbr\u003e\u003cbr\u003eWhen the L2 to N is higher than 260V, after 5 seconds of D-T setting, L2turn off the output. When the voltages L2 to N return to the normal range, L2 turn on the output after 10 seconds of R-T setting.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003e-Warnings-\u003c\/p\u003e\n\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003ePlease use the device according to the manual.\u003cbr\u003eDon't use the device in wet.\u003cbr\u003elnclude a switch and circuit breaker in the assembly.\u003cbr\u003ePut the switch and circuit breaker nearby the device,operator can reach easily.\u003cbr\u003eMark the swith and circuit breaker as releasingconnection for device.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eConnection Diagram\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg style=\"margin-bottom:10px\" class=\"detail-desc-decorate-image\" width=\"579\" height=\"472\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sc4c7faf5610a467fbe794dd8141eb5c95.png\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eDimensions\u003c\/p\u003e\n\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eAVR-3S-63A\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg style=\"margin-bottom:10px\" class=\"detail-desc-decorate-image\" width=\"595\" height=\"383\" src=\"https:\/\/ae01.alicdn.com\/kf\/S85f3f8fd90704d1ab442770749732624V.jpg\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eAVR-3S-80\/100A\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg style=\"margin-bottom:10px\" class=\"detail-desc-decorate-image\" width=\"562\" height=\"328\" src=\"https:\/\/ae01.alicdn.com\/kf\/S9d1577ddecc64f2abcdedf44f4921182N.jpg\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eSpecifications\u003c\/p\u003e\n\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eOperation Voltage(Un)....: 3x380V+Neutral\u003cbr\u003eOperation Frequecey.......: 50\/60Hz\u003cbr\u003eOperating Power..: \u0026lt;6VA\u003cbr\u003eOperating Temp...: -20°C.....+55°C\u003cbr\u003eOver-current Set(A\u0026gt;)...: 63A(1 - 40A); \u003cbr\u003e80A(1 - 80A);100A(1 - 100A)\u003cbr\u003eHigh Voltage Set(U\u0026gt;)....: 230 - 300V + Off\u003cbr\u003eLow Voltage Set(U\u0026lt;).....: 110 - 210V + Off\u003cbr\u003eLow Votage Fuse(U\u0026lt;\u0026lt;)......: 115V(Fixed)\u003cbr\u003eDelay Time.............: 0.1 - 20sec.\u003cbr\u003eReset Time.............: 0.1 - 300sec.\u003cbr\u003eDisplay.......: 3x6 digit LED display 5Leds\u003cbr\u003eMeasurement Precision..: ±1%\u003cbr\u003eConnecction Type...: Terminal Commection\u003cbr\u003eOperating Altitude..: \u0026lt;2000meter\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_image\"\u003e\u003cimg style=\"margin-bottom:10px\" class=\"detail-desc-decorate-image\" width=\"744\" height=\"561\" src=\"https:\/\/ae01.alicdn.com\/kf\/H89af765c27d04173aeee182b9ca7df05D.jpg\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_image\"\u003e\u003cimg style=\"margin-bottom:10px\" class=\"detail-desc-decorate-image\" width=\"744\" height=\"561\" src=\"https:\/\/ae01.alicdn.com\/kf\/H8a87f7a941634d5ea8a22cfbd60fed2co.jpg\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Yoeruyo","offers":[{"title":"100A","offer_id":55428737204523,"sku":"5:144170022#100A","price":152.91,"currency_code":"USD","in_stock":true},{"title":"80A","offer_id":55428737237291,"sku":"5:200004763#80A","price":134.6,"currency_code":"USD","in_stock":true},{"title":"63A","offer_id":55428737270059,"sku":"5:200004182#63A","price":124.11,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/5744\/8747\/files\/Sddbc376543c74d4f95e2a25d60213e0eI.webp?v=1788583476","url":"https:\/\/yoeruyo.com\/products\/samwha-dsp-avr-3s-xxa-3x380v-nuetral-adjustable-current-voltage-non-sync-relay-63a-80a-100a","provider":"Yoeruyo","version":"1.0","type":"link"}