{"product_id":"samwha-dsp-avr-xx-dual-display-adjustable-voltage-and-over-current-protection-relay-40a-63a","title":"Samwha-Dsp AVR-XX Dual Display Adjustable Voltage and Over-current Protection Relay 40A,63A","description":"\u003ch1\u003eSPECIFICATIONS\u003c\/h1\u003e\u003cp\u003e\u003cspan\u003eBrand Name\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003esamwhadsp\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eCertification\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eCE\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eChoice\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eyes\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eContact Load\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eHigh Power\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eEU LVD Voltage\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eHigh voltage: Above 50Vac or 75Vdc\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eHigh-concerned chemical\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003enone\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eModel Number\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eAVR-XX\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOrigin\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eMainland China\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003ePower Source\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eAc\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eProtect Feature\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eSealed\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eUse\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eProtective\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eVoltage\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e220V\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eis_customized\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eYes\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003esemi_Choice\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eyes\u003c\/span\u003e\u003c\/p\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eGeneral\u003c\/p\u003e\n\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eAVR Current \u0026amp; voltage protection relay is designed to protect devices with sensitive operating voltage \u0026amp; currentvalues from errorsthat may arise from mains voltage and Overload.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eDevice Usage and Principle of Operation\u003c\/p\u003e\n\u003cp style=\"font-weight:normal\"\u003eMake the connections of the device according to the connection type. Otherwise, the device may be damaged. Adjust the over-current andhigh \u0026amp; low voltage and settings of the device according to the coperating current and voltage values of the load you will use.\u003cbr\u003e\u003cbr\u003eOver-current Error state: If the current value is under the current set values (when the device is not in error), the current value risesabove the current set value, the device waits for the set error waiting time, then the device de-energizes the relay , the error led lurn on, the overload value displayed on the current display flashes throughout the error period.\u003cbr\u003e\u003cbr\u003eVoltage Error state: If the mains (input) voltage value is between the high and Low voltage set values (when the device is not in error), the mains (input) voltage value rises above the high voltage set value or under below the low voltage set value; the devicewaits for the set error waiting time, then the device de-energizes the relay, the error led lurn on, the mains linputl voltage value displayed on the voltage display flashes throughout the error period.\u003cbr\u003e\u003cbr\u003eExit the Over-current Error state: After eliminating the load over-current fault, Press twice the on\/off key to manual reset or cut off the power supply.\u003cbr\u003eNote_1: Manual reset is to avoid secondary damage to the system by automatically resetting the system without excluding over-current or short circuit.\u003cbr\u003e\u003cbr\u003eExit voltage error state: When the mains (input) voltage value returns to normal \/ when the reaches a value between thehigh and Low voltage set values the device waits for the set reset waiting time, then the device energizes the relay. the error led turns off, the out led turns on.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eDisplay and Buttons\u003c\/p\u003e\n\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003e1 - SET Button:This button is used to save after setting\/changing Over-current values \u0026amp; high\/low voltage setting values and error wait time.\u003cbr\u003e\u003cbr\u003e2 - UP Button: Increase the required value.\u003cbr\u003e\u003cbr\u003e3 - Down Button: Reduce the required value.\u003cbr\u003e\u003cbr\u003e4 - Manual On\/Off Button: For close the device output.In thisstate, the screen will display \"off\" and the device cannot be automatic reset. Press this button again to Switch on the device intouse again (No failure premise).\u003cbr\u003e\u003cbr\u003e5 - Current Display\u003cbr\u003e1St Display Group: During normal operation, the input (mains) voltage value is displayed here,the screen lights up steadily when not in errorstate,the display flashes in case of error (high or low voltage).During the programming process, the value of the relevant program is shownon the display (Over-current and high\/low voltage, error wait,reset wait setting values].\u003cbr\u003e\u003cbr\u003e6 - Voltage Display\u003cbr\u003e2St Display Group: During normal operation, current value is displayed here, the screen lights up steadily when not in error state,the display fashes in case of error (over-current). During the programming process, the numeric value of the relevant program is displayed here.\u003cbr\u003e\u003cbr\u003e7 - LEDs:\u003cbr\u003e A\u0026gt;:Light up when an over-current fault occurs.\u003cbr\u003e V\u0026gt;:Light up when an high voltage fault occurs.\u003cbr\u003e V\u0026lt;: Light up when an low voltage fault occurs.\u003cbr\u003e 0ut: Lights up when the device starts to output.\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg class=\"detail-desc-decorate-image\" width=\"340\" height=\"401\" src=\"https:\/\/ae01.alicdn.com\/kf\/S040e8050af9d4edcb9139b3b5a9bf9a3Y.jpg\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003e-Setting Up the Device\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cimg class=\"detail-desc-decorate-image\" width=\"368\" height=\"237\" src=\"https:\/\/ae01.alicdn.com\/kf\/S9ac9080879c54fdba41a6c93c50496f1L.jpg\" slate-data-type=\"image\"\u003e\u003cimg class=\"detail-desc-decorate-image\" width=\"662\" height=\"731\" src=\"https:\/\/ae01.alicdn.com\/kf\/S264954eb1546431492c886cc0658d8c7N.jpg\" slate-data-type=\"image\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eConnection Diagram\u003c\/p\u003e\n\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eThe neutral an phase connetcion comes from the mainsmust be connected to the \"N\"and \"L\" terminalsat the \"lnput\" of the device. Neutral and Phase connectionof thedevices that are desired to be protected fromover andunder voltage should be taken from the \"N\" and“L”terminals in the \"Output\" part of the device.\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg class=\"detail-desc-decorate-image\" width=\"353\" height=\"390\" src=\"https:\/\/ae01.alicdn.com\/kf\/S7eb47a83335541c58bc5e1c7a9941c1cq.jpg\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eDimensions\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg class=\"detail-desc-decorate-image\" width=\"384\" height=\"272\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sbaf5a159c1424902912f4b7ae59d8fdbe.jpg\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eSpecifications\u003c\/p\u003e\n\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eRated Current....: 40A or 63A\u003cbr\u003eRated Voltage.......: 220VAC\u003cbr\u003eFrequency...............: 50\/60Hz\u003cbr\u003eProtection Range...: 0-450VAC\u003cbr\u003eOperating Temp...: -20°C.....+55°C\u003cbr\u003eOperating Power..: \u0026lt;4VA\u003cbr\u003eOperating Altitude..: \u0026lt;2000meter\u003cbr\u003eDisplay............: 2x3 Digit LED Display and 4 leds\u003cbr\u003eOver-current Set(A\u0026gt;)...: 40A(1-40A); 63A(1-63A)\u003cbr\u003eHigh Voltage Set(V\u0026gt;)..........:230-300V+Off\u003cbr\u003eLow Voltage Set(V\u0026lt;)..........:120-210V+Off\u003cbr\u003eLow Votage Fuse(V\u0026lt;\u0026lt;)......:115V(Fixed)\u003cbr\u003eOver-current Waitting........:2-600sec.\u003cbr\u003eHigh Voltage Waitting........:0.1sec.(Fixed)\u003cbr\u003eLow Voltage Waitting.........:0-10sec.\u003cbr\u003ePower On Delay Waitting...: 2-600sec.\u003cbr\u003eReset Waitting.....................:1-60sec.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_image\"\u003e\u003cimg style=\"margin-bottom:10px\" class=\"detail-desc-decorate-image\" width=\"644\" height=\"486\" src=\"https:\/\/ae01.alicdn.com\/kf\/H89af765c27d04173aeee182b9ca7df05D.jpg\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_image\"\u003e\u003cimg style=\"margin-bottom:10px\" class=\"detail-desc-decorate-image\" width=\"744\" height=\"561\" src=\"https:\/\/ae01.alicdn.com\/kf\/H8a87f7a941634d5ea8a22cfbd60fed2co.jpg\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Yoeruyo","offers":[{"title":"63A","offer_id":55428776198443,"sku":"241567442:9619527000#63A","price":80.87,"currency_code":"USD","in_stock":true},{"title":"40A","offer_id":55428776231211,"sku":"241567442:9619593645#40A","price":80.87,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/5744\/8747\/files\/Sedee1ce18aa34dfbbcabdacead124d4ex.webp?v=1788583644","url":"https:\/\/yoeruyo.com\/products\/samwha-dsp-avr-xx-dual-display-adjustable-voltage-and-over-current-protection-relay-40a-63a","provider":"Yoeruyo","version":"1.0","type":"link"}