{"product_id":"samwha-dsp-eocr-ds3-output-1c-slim-electronic-overload-relay-motor-protector-thermal-overload-relay-un-24-260vac-dc","title":"Samwha-Dsp EOCR-DS3 (Output (1c) Slim Electronic Overload Relay Motor Protector Thermal Overload Relay (Un:24-260VAC\/DC)","description":"\u003ch1\u003eSPECIFICATIONS\u003c\/h1\u003e\u003cp\u003e\u003cspan\u003eBrand Name\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003esamwhadsp\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eCertification\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eCE\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eContact Load\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eLow Power\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eCurrent Range(A)\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e0.5-6A \/ 3-30A \/ 5-60A\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eEU LVD Voltage\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eHigh voltage: Above 50Vac or 75Vdc\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eHigh-concerned chemical\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003enone\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eMain Circuit Wiring\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eThrough Core\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eModel Number\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eEOCRDS3\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOperating Voltage(Un)\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e24-260VAC\/DC\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOrigin\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eMainland China\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003ePower Source\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eAc\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eProtect Feature\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eSealed\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eProtected Object\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003emotor\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eRelay Output\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e1c\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eTheory\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eThermal Relay\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eUse\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eProtective\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eVoltage\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e220V\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eis_customized\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eYes\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003emodel\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eEOCR\u003c\/span\u003e\u003c\/p\u003e\u003cdiv class=\"detailmodule_text\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eFeatures\u003c\/p\u003e\n\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003e■ MCU(Microprocessor Control Unit)\u003cbr\u003e■ Slim compact design \u003cbr\u003e■ Multiple Protection Functions\u003cbr\u003e■ Independently Adjustable Starting Trip Delay \u0026amp; \u003cbr\u003eOperating Time\u003cbr\u003e■ PWR \u0026amp; Trip Indication LED\u003cbr\u003e■ Trip Indication and Trip Cause Display\u003cbr\u003e■ Manual Instantaneous \/ Electrical Remote Reset\u003cbr\u003e■ Ambient Insensitive\u003cbr\u003e■ Low Energy Consumption\u003cbr\u003e■ (No Volt Release \/ Fail-safe Operation)→N Type\u003cbr\u003e※ AC \/ DC Power Supply Universal\u003cbr\u003e※ 3-Phase Dedicated\u003cbr\u003e※ 3-Phase Dedicated\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eUsed for\u003c\/p\u003e\n\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003e- Low Voltage Induced Electromotor (600V Level) \u003cbr\u003eProtective Relay\u003cbr\u003e- Break-Down Watch Current Relay\u003cbr\u003e- Alternative Replacement for the Existing Relay\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eProtetcion\u003c\/p\u003e\n\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eProtective Item       Operating (Trip) Time\u003cbr\u003e\u003cbr\u003eOver-current      =    O-TIME\u003cbr\u003e\u003cbr\u003eStall                    =     4 set or less\u003cbr\u003e\u003cbr\u003ePhase Loss         =     D-TIME\u003cbr\u003e\u003cbr\u003eReverse phase    =    0.1 set\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eLED\u003c\/p\u003e\n\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eAmmeter Function:\u003cbr\u003eAfter the motor runs smoothly, turn the overcurrent setting knob slowly counter clockwise to the red indicator light, which is 100% of the actual running current. And then turn the knob clockwise to just turn off the red light at this point for the actual running current value of about 103%. \u003cbr\u003e\u003cbr\u003eRun \/ Operation Indicator:\u003cbr\u003eRelay Trip: Orange LED\u003cbr\u003ePower \/ normal operating status: Green LED\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eManual \/ Electric Reset\u003c\/p\u003e\n\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eWith test button held down,the orange LED is on and the product will trip after O-TIME.\u003cbr\u003e\u003cbr\u003eThe relay will be de-energized when RESET button is pushed or the control power is disconnected.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eSet\u003c\/p\u003e\n\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eAfter the installation is complete the settings as follows.\u003cbr\u003e\u003cbr\u003eSet knob: D-TIME(Delay Time) Set two to three seconds longer than the motor starting time.\u003cbr\u003e\u003cbr\u003eSet knob: O-TIME(Over-current run time) Set less than the motor's endurance time with over-current.\u003cbr\u003e\u003cbr\u003eSet knob: Load(Rated Current) Set over 110% of the motor's rated current of under 120% of its operating current\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eTEST Instruction\u003c\/p\u003e\n\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eWith test button held down,the orange LED is on and the product will trip after O-TIME.\u003cbr\u003e\u003cbr\u003eThe relay will be de-energized when RESET button is pushed or the control power is disconnected.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eLED Indication\u003c\/p\u003e\n\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eItem           PWR(Green)LED          Trip(Orange)LED\u003cbr\u003e\u003cbr\u003e Power                   Blink                                  ×\u003cbr\u003e\u003cbr\u003eStarting                 Blink                              Flash\u003cbr\u003e\u003cbr\u003eNormal Running     ○                                    ×\u003cbr\u003e\u003cbr\u003eOver-current            ○                                  Flash\u003cbr\u003e\u003cbr\u003eTrip                           ×                                    ○\u003cbr\u003e \u003cbr\u003eStall                          ×                                  Blink\u003cbr\u003e\u003cbr\u003ePhase loss              ×                                  Blink\u003cbr\u003e\u003cbr\u003eReverse phase        Bink                            Flash\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eSpecifications\u003c\/p\u003e\n\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eCurrent Range............ : Type05) 0.5-6A\u003cbr\u003e\u003cbr\u003eType30) 3-30A\u003cbr\u003e\u003cbr\u003eType60) 5-60A\u003cbr\u003e\u003cbr\u003eType600) Use an external \u003cbr\u003eCT(secondary 5A)over 60A with 05 type.\u003cbr\u003e\u003cbr\u003eOperating Voltage(Un).:   Type220) 24-260VAC\/DC\u003cbr\u003e\u003cbr\u003eOperating Frequency....: 50\/60Hz\u003cbr\u003e\u003cbr\u003eOperating Power...........: \u0026lt;2W\u003cbr\u003e\u003cbr\u003eOperating Temperature: -20℃·····+55℃\u003cbr\u003e\u003cbr\u003eWaiting(t)......................: D-Time 0.2-30s\u003cbr\u003eO-Time 0.2-10s\u003cbr\u003e\u003cbr\u003eAsymmetry Set.............: %±10\u003cbr\u003e\u003cbr\u003eContact.........................: 5A 250VAC Resistive Load\u003cbr\u003e\u003cbr\u003eConnection Diagrams..: 35mm Din Rail(D) or \u003cbr\u003ePane(P)\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eDimensions\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg style=\"margin-bottom:10px\" class=\"detail-desc-decorate-image\" width=\"450\" height=\"164\" src=\"https:\/\/ae01.alicdn.com\/kf\/H910e530c82ec4717959f2c66584d36e1d.jpg\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eConstruction\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg style=\"margin-bottom:10px\" class=\"detail-desc-decorate-image\" width=\"450\" height=\"281\" src=\"https:\/\/ae01.alicdn.com\/kf\/H224b70a8d4bf4cf194e05286dc13e028I.jpg\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eConnection Diagram\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg style=\"margin-bottom:10px\" class=\"detail-desc-decorate-image\" width=\"450\" height=\"522\" src=\"https:\/\/ae01.alicdn.com\/kf\/H13c1050f2b4a49f9a28ab4e2c4b45618f.jpg\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_image\"\u003e\n\u003cimg style=\"margin-bottom:10px\" class=\"detail-desc-decorate-image\" width=\"750\" height=\"566\" src=\"https:\/\/ae01.alicdn.com\/kf\/Hbd85dd5417844ad4ad47f3ac5783b67aD.jpg\" slate-data-type=\"image\"\u003e\u003cimg style=\"margin-bottom:10px\" class=\"detail-desc-decorate-image\" width=\"750\" height=\"566\" src=\"https:\/\/ae01.alicdn.com\/kf\/Hc5ee445b991d433d94be28d219f76b97N.jpg\" slate-data-type=\"image\"\u003e\n\u003c\/div\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Yoeruyo","offers":[{"title":"5-60A","offer_id":55428811096363,"sku":"5:200004183#5-60A","price":87.39,"currency_code":"USD","in_stock":true},{"title":"0.5-6A","offer_id":55428811129131,"sku":"5:200004763#0.5-6A","price":87.39,"currency_code":"USD","in_stock":true},{"title":"3-30A","offer_id":55428811161899,"sku":"5:200004182#3-30A","price":87.39,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/5744\/8747\/files\/H46a81201e8594645b27423e1b029f1149.webp?v=1788583936","url":"https:\/\/yoeruyo.com\/products\/samwha-dsp-eocr-ds3-output-1c-slim-electronic-overload-relay-motor-protector-thermal-overload-relay-un-24-260vac-dc","provider":"Yoeruyo","version":"1.0","type":"link"}