{"product_id":"samwha-dsp-hp-54-4-step-ventilation-temperature-controller-with-ntc-sensor","title":"Samwha-Dsp HP-54 4-Step Ventilation \u0026 Temperature Controller With NTC Sensor","description":"\u003ch1\u003eSPECIFICATIONS\u003c\/h1\u003e\u003cp\u003e\u003cspan\u003eBattery Included\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eno\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eBrand Name\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003esamwhadsp\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eCable length\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e2m\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eCertification\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eCE\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eElectronic\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNo\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eHigh-concerned chemical\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003enone\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOrigin\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eMainland China\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eTheory\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eTemperature Controller\u003c\/span\u003e\u003c\/p\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-family:OpenSans;font-size:20px;font-weight:900;line-height:28px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-title\"\u003eMain Settings---------\u003c\/p\u003e\n\u003cp style=\"font-weight:bold\"\u003eHeat Temperature Setting\u003cbr\u003e\u003cbr\u003ePress HEAT:\u003cbr\u003eThis message will be displayed of the\u003cbr\u003eset heat temperature value press + or - to modify, press HEAT to exit.\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg style=\"margin-bottom:10px\" class=\"detail-desc-decorate-image\" width=\"273\" height=\"171\" src=\"https:\/\/ae01.alicdn.com\/kf\/S2e419b5ace584aa7afdbde382fbd14f6h.png\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-weight:bold\"\u003eVentilation Temperature Setting\u003cbr\u003ePress VENT:\u003cbr\u003eThis message will be displayed is of the set ventilation temperature value (start first step)\u003cbr\u003e\u003cbr\u003ePress + or - to modify, press VENT to confirm. At this point: This message is displayed, representing theminimum ventilation step (*).\u003cbr\u003e\u003cbr\u003ePress + or - to modify, press VENT to confirm. At this point: This message is displayed, representing themaximum ventilation step (*).\u003cbr\u003e\u003cbr\u003ePress + or - to modify, press VENT to confirm.\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg style=\"margin-bottom:10px\" class=\"detail-desc-decorate-image\" width=\"273\" height=\"171\" src=\"https:\/\/ae01.alicdn.com\/kf\/S3a770751a3db440bbfbf229724888c5ep.png\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-weight:bold\"\u003elf the minimum speed is set to 0, this message displayed is of the Set Shutter Running Time (seconds).\u003cbr\u003ePress + or - to modify, press VENT to confirm. At this point: this message will be displayed of the Shutter Dwell Time (sec.).\u003cbr\u003ePress + or - to modify, press VENT to confirm. At this point: this message will be displayed of the shut ventilation speed number.\u003cbr\u003ePress + or - to modify, press VENT to exit.\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg style=\"margin-bottom:10px\" class=\"detail-desc-decorate-image\" width=\"273\" height=\"171\" src=\"https:\/\/ae01.alicdn.com\/kf\/Scbbb5fd837354cd1add460c8c03b69ee9.png\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-weight:bold\"\u003eAlarm Parameter Setting.\u003cbr\u003ePress ALARM :\u003cbr\u003eThis message will be displayed of the Set Minimum Alarm temperature value. Press + or - to modify, press ALARM to confirm.\u003cbr\u003e\u003cbr\u003eAt this point: this message will be displayed of the set Maximum Alarm temperature value. Press + or - to modify, press ALARM to exit.\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg style=\"margin-bottom:10px\" class=\"detail-desc-decorate-image\" width=\"273\" height=\"171\" src=\"https:\/\/ae01.alicdn.com\/kf\/S9818cd6330824bddb301d45f714c86a90.png\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-weight:bold\"\u003eViewing Temperature Recording\u003cbr\u003ewill be displayed followed by\u003cbr\u003e°Maximum Temperature Recording.\u003cbr\u003ewill be displayed followed by\u003cbr\u003e°Minimum Temperature Recording.\u003cbr\u003e\u003cbr\u003eValues recorder are memory permanent stored: for memory clear keep pushed + keys for more than3 seconds: CLEA message will be composed on display before clearing operation.\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg style=\"margin-bottom:10px\" class=\"detail-desc-decorate-image\" width=\"273\" height=\"171\" src=\"https:\/\/ae01.alicdn.com\/kf\/S265891b4d9724edcb36a39a0293ca4e8C.png\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-weight:bold\"\u003eCOST Programming (System Constants)\u003cbr\u003e\u003cbr\u003ePress - \/ + at the same time for at least one second: the message C.0.S.t. will be displayed. Press than repeatedly ALARM until the message regarding the chosen variableis displayed (see table below): variable's value and message will be displayed. Press + or - to set a new value and then press ALARM to confirm. \u003cbr\u003e\u003cbr\u003eThe next system constant will then appear. You can press ALARM for at least 2 seconds to exit and return to the run mode.\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg style=\"margin-bottom:10px\" class=\"detail-desc-decorate-image\" width=\"273\" height=\"195\" src=\"https:\/\/ae01.alicdn.com\/kf\/S0c7f77f1d8c747988409631422b742b5N.png\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-weight:bold\"\u003eMess.    Valore              Meaning\u003cbr\u003ed.HEA    0.2°         °HEAT differential\u003cbr\u003e\u003cbr\u003erEL.1      0.0°         °Temperature set of step 1 \u003cbr\u003ereferred to the vEnt set.\u003cbr\u003e\u003cbr\u003erEL.2      1.0°        °Temperature set of step 2\u003cbr\u003ereferred  to the Step 1 start.\u003cbr\u003e\u003cbr\u003erEL.3      1.0°         °Temperature set of step 3\u003cbr\u003ereferred  to the Step 1 start.\u003cbr\u003e\u003cbr\u003erEL.4      1.0°         °Temperature set of step 4\u003cbr\u003ereferred  to the Step 1 start.\u003cbr\u003e\u003cbr\u003ed.FAn     0.2°         °Ventilation differential.\u003cbr\u003e\u003cbr\u003er.COL      6.0°         °COOL setting shift referring \u003cbr\u003eto vEnt set.\u003cbr\u003e\u003cbr\u003ed.COL     0.2°         °COOL differential.\u003cbr\u003e\u003cbr\u003etEnP        =1           Temperature unit(=1: ℃，=2: \u003cbr\u003e°F).\u003cbr\u003e\u003cbr\u003eAd.tE      0.0°        °Temperature sensor \u003cbr\u003eadjustment (+ or -).\u003cbr\u003e\u003cbr\u003etYPE         1          Start ventilation actioning \u003cbr\u003emode.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e1)For more details see Operative Diagrams\u003cbr\u003e2)You can correct the readings on the sensor (+ or -).\u003cbr\u003e3)Different mode of ventilator initial start-up optionally settable (step from 0 to 1 speed).\u003cbr\u003etYPE= 1 : 0 to 1 step become in normal mode.\u003cbr\u003etYPE= 2 : 0 to 1 step become with a momentary 10 seconds at speed 2.\u003cbr\u003etYPE= 3 : 0 to 1 step become with a momentary 5 seconds at speed 3.\u003cbr\u003etYPE= 4 : 0 to 1 step become with a momentary 5 seconds at speed 4.\u003cbr\u003etYPE=13 : Heating mode ventilation.\u003cbr\u003etYPE=14 : Progressive ventilation contacts (On-Off regulation type).\u003cbr\u003eOptions 2, 3 , 4 permits to make an easy opening of shutter models ventilators.\u003cbr\u003eOption 13 permits Heater mode ventilation (low temperature = higt speed; in other options high\u003cbr\u003etemperature= high speed).\u003cbr\u003eOption 14 permits On-Off regulation mode (in other condition regullation is for variable speed control).\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-weight:bold\"\u003ePreset Programs (bootstrap)\u003cbr\u003e\u003cbr\u003eThis processor is already programmed with the following (variable) settings.\u003cbr\u003eTo return to these settings at any time you may:\u003cbr\u003ePower off the processor, press MAX VENT key and keep it pressed giving power on:  message will be displayed (release now MAX VENT key).\u003cbr\u003eHEAt = 20.0° vEnt = 25.0° SP._ _=0 SP.--= 4 AL._ _=10.0° AL.-- = 40.0°\u003cbr\u003et.on = 10\"t. oF = 60\" SP.--= 0    The COSt values are shown in COSt Promagramming.\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg style=\"margin-bottom:10px\" class=\"detail-desc-decorate-image\" width=\"273\" height=\"195\" src=\"https:\/\/ae01.alicdn.com\/kf\/S020bcbe16c6942e191242a6bee7f4707u.png\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-weight:bold\"\u003eManual Mode\u003cbr\u003e\u003cbr\u003eln some start-up conditions may be useful to work in \"manual\" mode:\u003cbr\u003ePower off the processor, press + key and keep it pressed giving power on: HAnd message will be displayed (release now + key). Push +until is displayed number required to be handed (see table State indication lamps) and push ALARM for activing relay. Pushing again + for increase relay number previous relay is disactivated. You can press ALARM key for a least two seconds to escape and return to the Run Mode.\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg style=\"margin-bottom:10px\" class=\"detail-desc-decorate-image\" width=\"273\" height=\"195\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sad142fc5fb4e46308d7f0b9830122ffaT.png\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-weight:bold\"\u003eOperative Diagrams\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg style=\"margin-bottom:10px\" class=\"detail-desc-decorate-image\" width=\"503\" height=\"571\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sea12b8b66601499d9c3b68f3aa3368f1C.png\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-weight:bold\"\u003eStatus Indication Lamps\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg style=\"margin-bottom:10px\" class=\"detail-desc-decorate-image\" width=\"501\" height=\"327\" src=\"https:\/\/ae01.alicdn.com\/kf\/S93f4c735e44c4d70bef7cc1a5045ecc9R.png\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_text-image\"\u003e\n\u003cp style=\"font-weight:bold\"\u003eInstallation\u003cbr\u003e\u003cbr\u003eHow to connect the line:\u003cbr\u003eConnect 230V line on terminals L-N.Protect supply with adequate fuse.\u003cbr\u003eHow to connect the sensors:\u003cbr\u003eConnect the provided sensor as shown in the diagram. For remote connections use astandard 0.5-square millimeter two-pole wire, taking great care over the connections by insulating and sealing the joins carefully. -O.C.- is displayed when the temperature sensor wiringis open, -s.c.- is displayed when thetemperature sensor wiring is short circuit.\u003cbr\u003eHow to connect the contacts:\u003cbr\u003eOutput contacts are N.O. (Normally Opened free of voltage) on wich is apliablea 4AMP AC1 maximum load.\u003cbr\u003e3-4= Step 1 contact\u003cbr\u003e3-5= Step 2 contact\u003cbr\u003e3-6= Step 3 contact\u003cbr\u003e3-7= Step 4 contact\u003cbr\u003e11-12= Heat contact\u003cbr\u003e12-13= Cool contact\u003cbr\u003eAlarm and Cooling are available only with HPAL optional slot.\u003c\/p\u003e\n\u003cdiv\u003e\u003cimg style=\"margin-bottom:10px\" class=\"detail-desc-decorate-image\" width=\"489\" height=\"374\" src=\"https:\/\/ae01.alicdn.com\/kf\/S24af0415553b41ce9d1510fd452444111.png\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"detailmodule_image\"\u003e\u003cimg style=\"margin-bottom:10px\" class=\"detail-desc-decorate-image\" src=\"https:\/\/ae01.alicdn.com\/kf\/Hbd85dd5417844ad4ad47f3ac5783b67aD.jpg\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_image\"\u003e\u003cimg style=\"margin-bottom:10px\" class=\"detail-desc-decorate-image\" src=\"https:\/\/ae01.alicdn.com\/kf\/Hc5ee445b991d433d94be28d219f76b97N.jpg\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Yoeruyo","offers":[{"title":"Default Title","offer_id":55436223316267,"sku":"\u003cnone\u003e","price":147.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/5744\/8747\/files\/Sa438cd510ca6457bbf9ffb1133785b16J.webp?v=1788663584","url":"https:\/\/yoeruyo.com\/products\/samwha-dsp-hp-54-4-step-ventilation-temperature-controller-with-ntc-sensor","provider":"Yoeruyo","version":"1.0","type":"link"}