{"product_id":"voltage-relay-module-upper-lower-limit-detection-control-switch-off-on-over-voltage-protection-battery-charge-discharge-timing","title":"Voltage Relay Module Upper Lower Limit Detection Control Switch Off ON Over Voltage Protection Battery Charge Discharge Timing","description":"\u003ch1\u003eSPECIFICATIONS\u003c\/h1\u003e\u003cp\u003e\u003cspan\u003eBrand Name\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eAideepen\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eCertification\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNONE\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eContact Load\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eHigh Power\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eEU LVD Voltage\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eLow voltage: Below 50Vac or 75Vdc\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eHigh-concerned chemical\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003enone\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOrigin\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eMainland China\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003ePower Source\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eDC\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eProtect Feature\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eSealed\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eTheory\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eSolid State Relay\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eUse\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eGeneral Purpose\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eVoltage\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e12V\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eis_customized\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eYes\u003c\/span\u003e\u003c\/p\u003e\u003cdiv class=\"detailmodule_dynamic\"\u003e\u003ckse:widget data-widget-type=\"customText\" id=\"1005000001877612\" type=\"relation\"\u003e\u003c\/kse:widget\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_html\"\u003e\u003cdiv class=\"detail-desc-decorate-richtext\"\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cspan style=\"font-size:20px\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e1.Detection voltage range: 0-99.9V, with a minimum starting voltage of 0.1V\u003cbr\u003e2.Charging protection and discharge protection\u003cbr\u003e3.Overvoltage protection, undervoltage protection\u003cbr\u003e4.Fixed point pulse, stable performance\u003cbr\u003e5.Charge and discharge control, stable performance\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cspan style=\"font-size:20px\"\u003e\u003cstrong\u003eParameters:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003eVoltage: DC12V\u003cbr\u003eMaximum current of relay contacts: 12A\u003cbr\u003eDetection voltage range: 0-99.9V\u003cbr\u003eParameter Setting Description\u003cbr\u003eWhen powered on, the display will enter standby mode due to voltage. First, set two basic parameters, the lower limit voltage V1 and the upper limit voltage V2\u003cbr\u003e1. Press the setting button once to display \"F1\" flashing\u003cbr\u003e2. Press the setting key for the second time to display the default V1 value \"XX. X\" flashing. Press the \"Plus\" or \"Minus\" control keys to adjust the lower limit parameter V1\u003cbr\u003e3. Press the setting key for the third time to display the default V2 value \"XX. X\" flashing. Press the \"Plus\" or \"Minus\" button to adjust the upper limit parameter V2 (at this time, if V1 is greater than V2, it will be displayed. \"ERR\" error prompt, parameter needs to be changed, and it is necessary to keep V1 less than V2 as normal)\u003cbr\u003e4. Press the setting key for the fourth time, and the parameters will remain permanently and exit\u003cbr\u003e5. Press the \"Minus\" button for 3 seconds in standby mode to turn off the display, and press it again for 3 seconds to turn on the display. Designed to reduce power consumption\u003cbr\u003eFunction Description\u003cbr\u003e1. F-1 charging monitoring: When the measured voltage is lower than the voltage V1, the relay is closed, and when the voltage is higher than V2, the relay is disconnected\u003cbr\u003e2. F-2: Discharge monitoring: When the measured voltage is higher than the voltage, V2 relay is closed, and the voltage is lower than V1 relay is disconnected\u003cbr\u003e3. F-3: Off range pull-in: When measuring voltage, the relay is disconnected between V1 and V2, and other states of relay pull-in are introduced\u003cbr\u003e4. F-4: In range pull-in: When the measured voltage is between V1 and V2, the relay pulls in and disconnects in other states\u003cbr\u003e5. F-5: Fixed point monitoring: When the measured voltage is higher than V1, the relay is closed and lower than V1, the relay is disconnected\u003cbr\u003e6. F-6: Fixed point self-locking monitoring: When the measured voltage is higher than V1, the relay will remain engaged until manually powered off\u003cbr\u003e7. F-7: Fixed point pulse monitoring: When the measured voltage is equal to V1 (up and down floating 0.1V) each time, the relay outputs a jog signal\u003cbr\u003e8. F-8: New feature, voltage error correction, range ± 5.0V.\u003cbr\u003eSupplementary Setting Method\u003cbr\u003eAfter setting the F-1, all other functional parameters are set using the F-1 parameters. After pressing the setting button, F-1 will flash, and then press+or - to adjust the function number. After reaching a certain function number, press the setting button again and it will be OK. After pressing the setting button, F-1 will flash, and then press+or - to adjust the function number. After reaching a certain function number, press the setting button again and it will be OK.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size:20px\"\u003e\u003cstrong\u003ePackage include:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003eRelay module *1\u003cbr\u003e\u003cbr\u003e\u003cimg class=\"wscnph\" src=\"https:\/\/ae01.alicdn.com\/kf\/S0a00275e6c874b88b7684a1e6bd417d61.jpg\" slate-data-type=\"image\"\u003e\u003cimg class=\"wscnph\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sc31bfdf0eca94e749797c1b29f1a9f135.jpg\" slate-data-type=\"image\"\u003e\u003cimg class=\"wscnph\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sb11a7ae490b54540b4c19db839993550T.jpg\" slate-data-type=\"image\"\u003e\u003cimg class=\"wscnph\" src=\"https:\/\/ae01.alicdn.com\/kf\/S3d699a7c11a64ac6a389793f1adf364ay.jpg\" slate-data-type=\"image\"\u003e\u003cimg class=\"wscnph\" src=\"https:\/\/ae01.alicdn.com\/kf\/Seeb3876a9f0d49958a449e8427730122p.jpg\" slate-data-type=\"image\"\u003e\u003cimg class=\"wscnph\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sdc6edf03a96f469993ba86b6963b57dam.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Yoeruyo","offers":[{"title":"Default Title","offer_id":55428742152491,"sku":"\u003cnone\u003e","price":19.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/5744\/8747\/files\/S0a00275e6c874b88b7684a1e6bd417d61.webp?v=1788583497","url":"https:\/\/yoeruyo.com\/products\/voltage-relay-module-upper-lower-limit-detection-control-switch-off-on-over-voltage-protection-battery-charge-discharge-timing","provider":"Yoeruyo","version":"1.0","type":"link"}