SPECIFICATIONS

Brand Name: sincere&promise

Choice: yes

Condition: New

High-concerned chemical: none

Origin: Mainland China

Supply Voltage: 5V

Type: Voltage Regulator

 
 

Product introduction

1. The module USES the authentic quality 30 a maximum load relay normally open interface: AC 250V / 30A, DC 30V / 30A;

2. The patch optical coupling isolation, driving ability strong stable performance; Trigger current 5mA;

3. modules, working voltage of 5V, 12V, 24V;

4. module can be set up by high level or low level trigger

5. interface design, humanization, all interface can connect directly by patch panel is convenient

6. module size: 72 mm * 39.9 mm * 20.9 mm (length * width * height)

Module size (with module framework): 42.2 mm * 86.5 mm * 44.3 mm

7. product net weight: 46 g; 82 g (including module framework)

8. there are four fixed bolt hole, hole is 3.1 mm spacing of 44.5 mm * 27.5 mm

Product parameters





1 way

2 way

The power supply voltage

5V/12V/24V

5V/12V/24V

The static current

5MA

5MA

Working current limit

190MA/80MA/50MA

190MA/80MA/50MA

Trigger mode

Low level trigger

Low level trigger

High level trigger

High level trigger

Trigger voltage range: refer to the following

Trigger voltage range: refer to the following

Load voltage

DC 30V or AC 250V

DC 30V or AC 250V

Load voltage

30A

30A

Relay for life

About 100000 times more

About 100000 times more

Size (length * width * height)

39.9*72.0*21.1mm

70.0*72.1*20.9mm

Location hole

34.36*66.65mm

67.5*69.5mm




Note: customers should buy 5 V voltage slightly higher voltage is only 5.5 V or 6 V can trigger voltage relay!

Trigger voltage range:




Module that electronic

The power of the module must be a dc voltage must be compatible with the relay voltage

1. The dc + (connected to the anode) dc and dc - (connected to a dc cathode) is used to connect the power supply and optional module voltage 5 v / 12 v / 24 v (mainly module).

2. IN the module is triggered. When there is a trigger signal, the output of the relay and the switch will close load is conductive.

3. high level and low level trigger the meaning of:

High level trigger: called PNP trigger in industrial control, the positive triggered, namely on the triggering end of trigger voltage between the cathode voltage when the relay is closed. The diagram below: (illustration only trigger mode, is not this product parameters)

Low level trigger: in industrial control, it's called the NPN triggers and negative trigger, namely on the trigger and when electrode voltages for OV or close to OV, relay is closed. Trigger methods described as follows: (illustration only, not the parameters of the product)

Interface specification

1. DC +: Module DC power supply positive electrode (trigger terminal voltage positive electrode)

2. DC -: DC power supply module cathode (Trigger voltage across the cathode)

3. IN: signal trigger terminal (default trigger voltage and power is the same)

4. High/low level trigger mode selection:

as shown IN figure: jump line and L end connection, for low level trigger IN end, with the H connection for high level trigger

5. normally closed end (NC): relay normally closed end

6. common(COM): relay public side

7. Normally open (NO): relay normally open

Note:

1. The source and load used in the parameter scope, please do not use beyond.

2. The rated load and life expectancy is a reference, according to different environmental factors. Larger load performance and kind friend, so be in actual or simulated use for confirmation.

3. The module's load capacity is strongly influenced by environmental temperature and its temperature rise, need according to the actual working environment, use air for heat dissipation, asks to install in the convection environment is good

4. The high temperature electric durability; Module used in high temperature, electrical durability, lower than the room temperature using so please march confirmed in actual use.








Free Shipping Over $199
  • Standard Shipping: Standard Shipping (12–18 Business Days)
  • Express Shipping: Expedited Shipping (5–9 Business Days)
  • Free Shipping: Orders over $199 qualify automatically
  • Tracking: Full tracking number provided for all orders
30-Day Return Policy
  • Returns: 30-day hassle-free return window
  • Condition: Items must be unused and in original packaging
  • Refund: Full refund processed within 3-5 business days
Why Choose Us?
  • Factory Direct: ISO/TS 16949 certified manufacturer
  • Quality: 100% electrical continuity tested before shipment
  • Experience: 15+ years in automotive connector industry
  • Support: Professional technical support available
Secure Payment Latest encryption technology
Money-Back Guarantee 30-day hassle-free returns
Quality Assured Factory certified products
Global Fast Shipping Worldwide express delivery

You may also like

Contact us

Subscribe to our emails

Be the first to know about new collections and special offers.