Skip to product information
N4KTF32 is the 32CH RS485 K-type thermocouple collector developed and produced for the first time by eletechsup. Through this module, the temperature value of the K thermocouple can be converted into a digital quantity and transmitted through RS485. If the accuracy requirements are not high, you can use version A. If the accuracy requirements are high, it is recommended to use version B.
Function:
A version module:
Power supply : DC 7-25V (Recommended 12V 24V)
Working current: 20-30MA
Temperature measurement channel: 32
Temperature measurement chip: MAX6675ISA+
Temperature measurement range: 0-1024℃
Resolution: 12 bits, 0.25℃ resolution
Accuracy: The thermocouple has an accuracy of ±4℃( 0℃ to +700℃),Accuracy is poor.
MODBUS RTU protocol, 03/04 read command, 06/16 write command.
RS485 bus interface, Default baud rate 9600BPS
Compatible sensor: K-type thermocouple
Dimensions: 285 X 106 X 40MM(With DIN Housing)
Weight: 430grams(With DIN Housing)
B version module:
Power supply : DC 7-25V (Recommended 12V 24V)
Working current: 20-30MA
Temperature measurement channel: 32
Temperature measurement chip: MAX31855KASA+
Temperature measurement range: -200℃ to +1350℃
Resolution: 14 bits, 0.25°C resolution
Accuracy: The thermocouple has an accuracy of ±2℃( -200℃to +700℃),Accuracy is relatively good.
MODBUS RTU protocol, 03/04 read command, 06/16 write command.
RS485 bus interface, default baud rate 9600BPS
Compatible sensor: K-type thermocouple
Dimensions: 285 X 106 X 40MM(With DIN Housing)
Weight: 430grams(With DIN Housing)
NOTE!!!
The K thermocouple acquisition port is easily damaged, please do not input a voltage greater than 3V, and please prevent static electricity. If the acquisition port is damaged, it can be repaired by replacing the MAX6675ISA+/MAX31855KASA+ IC.
How to use:
1 Connect the power port to the power supply (DC 12V recommended)
2 Connect to RS485 bus
3 Connect the K thermocouple probe
4 Power-on test

Note: The module will restore factory settings and automatically restart after the RES port is short-circuited for 5 seconds.
For protocol details, please refer to the ''N4KTF32 Modbus RTU Protocol''
32 Channel K-type Thermocouple Module Modbus RTU RS485 MAX6675 MAX31855 DC7-25V DIN Rail Temp Acquisition Industrial Monitor
$582.35
Sale price
$582.35
Regular price
$0.00
Description
SPECIFICATIONS
Brand Name: eletechsup
Choice: yes
Condition: New
High-concerned chemical: none
Origin: Mainland China
Type: Relay
is_customized: Yes
semi_Choice: yes
N4KTF32 is the 32CH RS485 K-type thermocouple collector developed and produced for the first time by eletechsup. Through this module, the temperature value of the K thermocouple can be converted into a digital quantity and transmitted through RS485. If the accuracy requirements are not high, you can use version A. If the accuracy requirements are high, it is recommended to use version B.
Function:
A version module:
Power supply : DC 7-25V (Recommended 12V 24V)
Working current: 20-30MA
Temperature measurement channel: 32
Temperature measurement chip: MAX6675ISA+
Temperature measurement range: 0-1024℃
Resolution: 12 bits, 0.25℃ resolution
Accuracy: The thermocouple has an accuracy of ±4℃( 0℃ to +700℃),Accuracy is poor.
MODBUS RTU protocol, 03/04 read command, 06/16 write command.
RS485 bus interface, Default baud rate 9600BPS
Compatible sensor: K-type thermocouple
Dimensions: 285 X 106 X 40MM(With DIN Housing)
Weight: 430grams(With DIN Housing)
B version module:
Power supply : DC 7-25V (Recommended 12V 24V)
Working current: 20-30MA
Temperature measurement channel: 32
Temperature measurement chip: MAX31855KASA+
Temperature measurement range: -200℃ to +1350℃
Resolution: 14 bits, 0.25°C resolution
Accuracy: The thermocouple has an accuracy of ±2℃( -200℃to +700℃),Accuracy is relatively good.
MODBUS RTU protocol, 03/04 read command, 06/16 write command.
RS485 bus interface, default baud rate 9600BPS
Compatible sensor: K-type thermocouple
Dimensions: 285 X 106 X 40MM(With DIN Housing)
Weight: 430grams(With DIN Housing)
NOTE!!!
The K thermocouple acquisition port is easily damaged, please do not input a voltage greater than 3V, and please prevent static electricity. If the acquisition port is damaged, it can be repaired by replacing the MAX6675ISA+/MAX31855KASA+ IC.
How to use:1 Connect the power port to the power supply (DC 12V recommended)
2 Connect to RS485 bus
3 Connect the K thermocouple probe
4 Power-on test

Note: The module will restore factory settings and automatically restart after the RES port is short-circuited for 5 seconds.
For protocol details, please refer to the ''N4KTF32 Modbus RTU Protocol''
Free Shipping Over $199
- Standard Shipping: Standard Shipping (12–18 Business Days)
- Express Shipping: Expedited Shipping (5–9 Business Days)
- Free Shipping: Orders over $199 qualify automatically
- Tracking: Full tracking number provided for all orders
30-Day Return Policy
- Returns: 30-day hassle-free return window
- Condition: Items must be unused and in original packaging
- Refund: Full refund processed within 3-5 business days
Why Choose Us?
- Factory Direct: ISO/TS 16949 certified manufacturer
- Quality: 100% electrical continuity tested before shipment
- Experience: 15+ years in automotive connector industry
- Support: Professional technical support available
You may also like
Blog posts
Title
An excerpt of your blog post's content
Title
Date|Author
Subscribe to our emails
Be the first to know about new collections and special offers.