Skip to product information
Product Name: 8CH Opto Isolated Modbus RTU RS485 IO Expansion Board DC7-25V ULN2803 300mA For PLC Smart Home CCTV PTZ
Package inlcuded:
1 PCS DC 7-30V 8DI-8DO Safety Barrier RS485 Digital Input & Output IO Module

1 Product description
8ch optoelectronic isolation digital input channel (NPN Low level input)
8ch optoelectronic isolation digital output channel (ULN2803 NPN output)
RS485 MODBUS RTU standard communication protocol
Netted with configuration software, PLC or industry touch panel
Communication circuit designed for thunder protection and interference immunity
Used for signal collection and control in industrial field
2 Specification
1 Working voltage: DC 7-25V (9V 12V 24V)
2 Working current: 8-50MA
3 8 port optically isolated input ports (NPN active low)
4 8 port Darlington tube outputs (ULN2803 NPN output), the maximum load current of each channel is 300MA
5 RS485 communication isolation protection 3000VDC, DI digital input port isolation protection 3000VDC
6 Standard MODBUS RTU command (function code, 05/06/15/16 Write, 01/02/03 Read )
7 Baud rates: 1200 2400 4800 9600 (default) 19200 38400 57600 115200
8 Parity bits: None (default) /Even /Odd
9 Installation method Standard DIN rail installation
10 Size : 125×110×22mm
11 Weight: 130 grams
3 Interface definition:
Vi : Power input+
G: Power input-
Vo: =Vi
DO1: digital output channel 1
DO2: digital output channel 2
DO3: digital output channel 3
DO4: digital output channel 4
DO5: digital output channel 5
DO6: digital output channel 6
DO7: digital output channel 7
DO8: digital output channel 8
DI1 : Digital input channel 1
DI2 : Digital input channel 2
DI3 : Digital input channel 3
DI4 : Digital input channel 4
DI5 : Digital input channel 5
DI6 : Digital input channel 6
DI7 : Digital input channel 7
DI8 : Digital input channel 8
A+: RS485 signal A+
B-: RS485 signal B-
For more information, please contact me
Application
PLC DIO Output expansion board
Smart Home,Home Automation ,Wiser Home;
PTZ CCTV Camera
Security Monitoring
Identification system;
Motor FW & BW
Automatic curtain control
Relay Solenoid valve
1 NPN Digital Input Wiring Diagram
2 NPN Digital output wiring diagram
Note: The Darlington tube has only two states of ''high resistance'' and ''conduction'', and the output level cannot be measured with a multimeter.


RS485 Networking Diagram

Modbus Rtu Register:
8CH Opto Isolated Modbus RTU RS485 IO Expansion Board DC7-25V ULN2803 300mA For PLC Smart Home CCTV PTZ
$152.78
Sale price
$152.78
Regular price
$0.00
Description
SPECIFICATIONS
Brand Name: eletechsup
Choice: yes
Condition: New
High-concerned chemical: none
Origin: Mainland China
Type: Relay
is_customized: Yes
semi_Choice: yes
Product Name: 8CH Opto Isolated Modbus RTU RS485 IO Expansion Board DC7-25V ULN2803 300mA For PLC Smart Home CCTV PTZ
Package inlcuded:
1 PCS DC 7-30V 8DI-8DO Safety Barrier RS485 Digital Input & Output IO Module

1 Product description
8ch optoelectronic isolation digital input channel (NPN Low level input)
8ch optoelectronic isolation digital output channel (ULN2803 NPN output)
RS485 MODBUS RTU standard communication protocol
Netted with configuration software, PLC or industry touch panel
Communication circuit designed for thunder protection and interference immunity
Used for signal collection and control in industrial field
2 Specification
1 Working voltage: DC 7-25V (9V 12V 24V)
2 Working current: 8-50MA
3 8 port optically isolated input ports (NPN active low)
4 8 port Darlington tube outputs (ULN2803 NPN output), the maximum load current of each channel is 300MA
5 RS485 communication isolation protection 3000VDC, DI digital input port isolation protection 3000VDC
6 Standard MODBUS RTU command (function code, 05/06/15/16 Write, 01/02/03 Read )
7 Baud rates: 1200 2400 4800 9600 (default) 19200 38400 57600 115200
8 Parity bits: None (default) /Even /Odd
9 Installation method Standard DIN rail installation
10 Size : 125×110×22mm
11 Weight: 130 grams
3 Interface definition:
Vi : Power input+
G: Power input-
Vo: =Vi
DO1: digital output channel 1
DO2: digital output channel 2
DO3: digital output channel 3
DO4: digital output channel 4
DO5: digital output channel 5
DO6: digital output channel 6
DO7: digital output channel 7
DO8: digital output channel 8
DI1 : Digital input channel 1
DI2 : Digital input channel 2
DI3 : Digital input channel 3
DI4 : Digital input channel 4
DI5 : Digital input channel 5
DI6 : Digital input channel 6
DI7 : Digital input channel 7
DI8 : Digital input channel 8
A+: RS485 signal A+
B-: RS485 signal B-
For more information, please contact me
Application
PLC DIO Output expansion board
Smart Home,Home Automation ,Wiser Home;
PTZ CCTV Camera
Security Monitoring
Identification system;
Motor FW & BW
Automatic curtain control
Relay Solenoid valve
1 NPN Digital Input Wiring Diagram
2 NPN Digital output wiring diagram
Note: The Darlington tube has only two states of ''high resistance'' and ''conduction'', and the output level cannot be measured with a multimeter.


RS485 Networking Diagram

Modbus Rtu Register:
Free Shipping Over $199
- Standard Shipping: Standard Shipping (12–18 Business Days)
- Express Shipping: Expedited Shipping (5–9 Business Days)
- Free Shipping: Orders over $199 qualify automatically
- Tracking: Full tracking number provided for all orders
30-Day Return Policy
- Returns: 30-day hassle-free return window
- Condition: Items must be unused and in original packaging
- Refund: Full refund processed within 3-5 business days
Why Choose Us?
- Factory Direct: ISO/TS 16949 certified manufacturer
- Quality: 100% electrical continuity tested before shipment
- Experience: 15+ years in automotive connector industry
- Support: Professional technical support available
You may also like
Blog posts
Title
An excerpt of your blog post's content
Title
Date|Author
Subscribe to our emails
Be the first to know about new collections and special offers.