Samwha-Dsp AVR-XXTF 3x380V+Nuetral Over-current And Voltage Protection Relay 63A,80A,100A

Samwha-Dsp AVR-XXTF 3x380V+Nuetral Over-current And Voltage Protection Relay 63A,80A,100A

80A / None Phase Sequency
$168.08
Sale price  $168.08 Regular price  $0.00
Skip to product information
Samwha-Dsp AVR-XXTF 3x380V+Nuetral Over-current And Voltage Protection Relay 63A,80A,100A
Samwha-Dsp AVR-XXTF 3x380V+Nuetral Over-current And Voltage Protection Relay 63A,80A,100A
$168.08
Sale price  $168.08 Regular price  $0.00
Size
Current Range
Description

SPECIFICATIONS

Brand Name: samwhadsp

Certification: CE

Choice: yes

Contact Load: High Power

EU LVD Voltage: High voltage: Above 50Vac or 75Vdc

High-concerned chemical: none

Model Number: AVR-XXTF

Origin: Mainland China

Power Source: Ac

Protect Feature: Sealed

Protection Item 1: Overvoltage

Protection Item 2: undervoltage

Protection Item 3: Over-current

Use: Protective

Voltage: 380V

is_customized: Yes

semi_Choice: yes

-General-

AVR Current & voltage protection relay is designed to protect devices with sensitive operating voltage & currentvalues from errorsthat may arise from mains voltage and Overload.

-Device Usage and Principle of Operation -

Make the connections of the device according to the connection type. Otherwise, the device may be damaged. Adjust the over-current andhigh & low voltage and settings of the device according to the coperating current and voltage values of the load you will use.

Over-current Error state: If the current value is under the current set values (when the device is not in error), the current value risesabove the current set value, the device waits for the set error waiting time, then the device de-energizes the relay , the error led lurn on, the overload value displayed on the current display flashes throughout the error period.

Voltage Error state: If the mains (input) voltage value is between the high and Low voltage set values (when the device is not in error), the mains (input) voltage value rises above the high voltage set value or under below the low voltage set value; the devicewaits for the set error waiting time, then the device de-energizes the relay, the error led lurn on, the mains linputl voltage value displayed on the voltage display flashes throughout the error period.

Exit the Over-current Error state: After eliminating the load over-current fault, Press twice the on/off key to manual reset or cut off the power supply.
Note_1: Manual reset is to avoid secondary damage to the system by automatically resetting the system without excluding over-current or short circuit.

Exit voltage error state: When the mains (input) voltage value returns to normal / when the reaches a value between thehigh and Low voltage set values the device waits for the set reset waiting time, then the device energizes the relay. the error led turns off, the out led turns on.

Phase sequence is available on AVR-XXTF.
When phase sequence is reversed, disallow output and phase range (X1) led is lighted.

-Display and Buttons-

1 - Over current setting knob

2 - High voltage setting knob

3 - Low voltage setting knob

4 - Delay time setting knob

5 - Reset time setting knob

6 - Manual On/Off Button:
For close the device output.In this state, the screen will display "off" and the device cannot be automatic reset. Press this button againto switch on the device intouse again (No failure premise).

7 - Current Display
1St Display Group: During normal operation,current value is displayed here, the screen lights up steadily when not in error state.the display flashesin case of error (over-current).
During the programming process,the value of the relevant program is shown on the display (Over-current and high/low volt, delay time.reset time setting values).

8 - Voltage Display
2St Display Group: During normal operation, the input voltage value is displayed here,the screen lights up steadily when not in error state.the display flashesin case of error(high or low voltage).


9 - LEDs:
A>:Light up when an over-current fault occurs.
V>:Light up when an high voltage fault occurs.

V<: Light up when an low voltage fault occurs.

X1:Light up when an phase sequence fault
occurs.(※Only the AVR-XXTF has this feature. )

0ut: Lights up when the device starts to output.

-Working-

Example: Set the low voltage value (U<) to 160V the high voltage value (U>) to 260V, the delay time of (D-T) is 5 sec, and the reset of (R-T) is 10 sec.

Make the connections of the device according to the connection type.

When any voltage of L1, L2, L3 to N is lower than 160V, after 5 seconds of D-T setting, L1, L2, L3 turn off the output. When the voltages L1, L2, L3 to N return to the normal range, L1, L2, and L3 turn on the output after 10 seconds of R-T setting.

When any voltage of L1, L2, L3 to N is higher than 260V, after 5 seconds of D-T setting. L1, L2, L3 turn off the output. When the voltages L1, L2, L3 to N return to the normal range, L1, L2, and L3 turn on the output after 10 seconds of R-T setting.

※AVR-XXTF type doesn't work if the phase sequence is incorrect.

-Warnings-

Please use the device according to the manual.
Don't use the device in wet.
lnclude a switch and circuit breaker in the assembly.
Put the switch and circuit breaker nearby the device,operator can reach easily.
Mark the swith and circuit breaker as releasingconnection for device.

Connection Diagram

Dimensions

AVR-63T/TF

AVR-80/100T/TF

Specifications

Operation Voltage(Un)....: 3x380V+Neutral
Operation Frequecey.......: 50/60Hz
Operating Power..: <6VA
Operating Temp...: -20°C.....+55°C
Over-current Set(A>)...: 63A(1 - 40A);
80A(1 - 80A);100A(1 - 100A)
High Voltage Set(U>)....: 230 - 300V + Off
Low Voltage Set(U<).....: 110 - 210V + Off
Low Votage Fuse(U<<)......: 115V(Fixed)
Delay Time.............: 0.1 - 20sec.
Reset Time.............: 0.1 - 300sec.
Display.......: 3x6 digit LED display 5Leds or
4Leds(AVR-XXT)
Measurement Precision..: ±1%
Connecction Type...: Terminal Commection
Operating Altitude..: <2000meter


Free Shipping Over $199
  • Standard Shipping: Standard Shipping (12–18 Business Days)
  • Express Shipping: Expedited Shipping (5–9 Business Days)
  • Free Shipping: Orders over $199 qualify automatically
  • Tracking: Full tracking number provided for all orders
30-Day Return Policy
  • Returns: 30-day hassle-free return window
  • Condition: Items must be unused and in original packaging
  • Refund: Full refund processed within 3-5 business days
Why Choose Us?
  • Factory Direct: ISO/TS 16949 certified manufacturer
  • Quality: 100% electrical continuity tested before shipment
  • Experience: 15+ years in automotive connector industry
  • Support: Professional technical support available
Secure Payment Latest encryption technology
Money-Back Guarantee 30-day hassle-free returns
Quality Assured Factory certified products
Global Fast Shipping Worldwide express delivery

You may also like

Contact us

Subscribe to our emails

Be the first to know about new collections and special offers.