DC 5V 12V 24V Voltage Relay Module Upper Lower Limit Detection Control Switch Off ON Over Voltage Protection Relay

DC 5V 12V 24V Voltage Relay Module Upper Lower Limit Detection Control Switch Off ON Over Voltage Protection Relay

5V
$20.03
Sale price  $20.03 Regular price  $0.00
Skip to product information
DC 5V 12V 24V Voltage Relay Module Upper Lower Limit Detection Control Switch Off ON Over Voltage Protection Relay
DC 5V 12V 24V Voltage Relay Module Upper Lower Limit Detection Control Switch Off ON Over Voltage Protection Relay
$20.03
Sale price  $20.03 Regular price  $0.00
Size
Description

SPECIFICATIONS

Brand Name: Gaqqee

Certification: CE

Choice: yes

Contact Load: High Power

EU LVD Voltage: Low voltage: Below 50Vac or 75Vdc

High-concerned chemical: none

Model Number: Voltage Relay Module

Origin: Mainland China

Power Source: DC,DC

Protect Feature: Sealed

Theory: Voltage relay

Use: General Purpose

Voltage: 24V

is_customized: no

semi_Choice: yes

DC 5V 12V 24V Voltage Relay Module Upper Lower Limit Detection Control Switch Off ON Over Voltage Protection Relay


Product features:
Powerful detection range of DC 0-99.9V, starting from 0.1V
Charge protection, discharge protection
Over-voltage protection, under-voltage protection
Fixed-point pulse, stable performance
Charge and discharge control, multiple supply voltages available 5V/12V/24V

Product parameters:
Detection voltage range: 0-99.9V (minimum 0.1V)
Operating voltage: DC 5V/12V/24V selectable
Maximum relay contact current: 12A (please leave a margin for use)
Product size: 56mm*44mm

Operation introduction:
1.In non-setting state, short press SET key, cyclic display: working mode -> lower voltage limit -> upper voltage limit.
2. In the non-setting state, press the SET key for 2 seconds to enter the parameter setting state; the display shows F01, press the +- key to select the parameter to be set, F01 (upper limit voltage), F02 (lower limit voltage), F03 working mode, F04 voltage calibration value.
3. After selecting the parameters to be set, short press SET key to enter the parameter setting state, press +- key to adjust, when the lower limit voltage is greater than or equal to the upper limit voltage, the display shows Err for 1 second to prompt the user. When the lower limit voltage is equal to the upper limit voltage, close the relay output function.
4. After setting the parameter value, short press SET to return to the parameter list.
5. After setting the parameters, long press SET for 2 seconds to exit and save the parameters.
6. In the non-setting state, press and hold the SET and + keys simultaneously for 2 seconds to restore the factory settings.
7 Press and hold - to turn off or on the digital tube to display the energy saving mode

Setting details:
F03 working mode Non-setting state
Press and hold SET to select F03 working mode, + and - to select the desired function and then press SET to save and exit.
Please note that before setting this parameter, please set the upper and lower voltage limits as necessary.
H-1, charge monitoring When the monitored voltage is lower than the lower limit voltage the relay is activated, above the upper limit voltage it is disconnected.
H-2, Discharge monitoring When the monitoring voltage is higher than the upper limit voltage, the relay opens below the

lower limit voltage.
H-3, Out-of-zone monitoring The relay opens when the monitored voltage is between the upper limit voltage and the lower limit voltage, the relay opens in other states
H-4 Intra-area suction When the monitoring voltage is between the upper and lower limit voltage the relay is activated, the other state relays are disconnected.
H-5 Fixed point monitoring Relays open when monitoring voltage is above the lower limit voltage, relays open below the lower limit voltage
H-6 Fixed-point self-locking monitoring When the monitoring voltage is higher than the lower voltage limit the relay opens and remains open until manual intervention or power failure
H-7 Fixed-point pulse monitoring When monitoring each time equal to the lower limit voltage (±0.1V) the relay outputs a flicker signal
F04 Calibration mode Non-setting state long press SET to enter, +- selection
The default is 0 error, if you need to set adjust as required, the
For example, the actual input voltage is 12.5V, the module shows 12.4V, at this time you can set the error to 0.1V, i.e. 12.4+0.1=12.5
For example, if the actual input voltage is 12.5V and the module shows 12.6V, the error can be set to -0.1V, i.e. 12.6-0.1=12.5

Product list:
1X module







Free Shipping Over $199
  • Standard Shipping: Standard Shipping (12–18 Business Days)
  • Express Shipping: Expedited Shipping (5–9 Business Days)
  • Free Shipping: Orders over $199 qualify automatically
  • Tracking: Full tracking number provided for all orders
30-Day Return Policy
  • Returns: 30-day hassle-free return window
  • Condition: Items must be unused and in original packaging
  • Refund: Full refund processed within 3-5 business days
Why Choose Us?
  • Factory Direct: ISO/TS 16949 certified manufacturer
  • Quality: 100% electrical continuity tested before shipment
  • Experience: 15+ years in automotive connector industry
  • Support: Professional technical support available