SPECIFICATIONS

Brand Name: EARU

Certification: CE,RoHS

Choice: yes

EAMT1 Rated Current: 16A

EAMT1 Voltage: AC/DC 12-240V

EU LVD Voltage: High voltage: Above 50Vac or 75Vdc

Function: Delay on, Delay off, Interval, Cycle, Single Shot, Pulse

High-concerned chemical: none

Model Number: EAMT1

Origin: Mainland China

Output Contact: 1NO1NC 2NO2NC

Power Source: Ac

Product Certification: CE/RoHS/REACH/SCCP

Product Name 1: Time Relay

Rated Frequency: 50/60Hz

Theory: Time Relay

Time Range: 0.1s-10days

Use: General Purpose

Voltage: 220V

is_customized: Yes

semi_Choice: yes

Functions Diagram

A:On Delay(Power On)

When the input voltage U is applied, timing delay t begins,Relay con-tacts R change state after time delay is complete.Contacts R return to theirshelfstatewheninputvoltageU is removed.Trigger switch is not used in this function.

B:Interval (Power On)

When input voltage U is applied,relaycontacts Rchange state immediately and timing cycle begins. When timedelayiscomplete,contactsreturnto shelf state. When input voltage U isremoved,contacts will also return to their shelfstate. Trigger switch is not used in this function.

C:Repeat Cycle(Starting Off)

When input voltage U is applied, time delay t begins.When time delay tis complete, relay contacts Rcharnge state for time delay t. This cycle will repeat until input voltage U is removed. Trigger switch is not used

in this function.

D:Repeat Cycle(Starting On)

When input voltage U is applied, relay contacts R change state imme-diately and time delay t begins. When time delay tis complete,contacts return to their shelf state for time delayt.Thiscyclewillrepeatuntilinput voltage U is removed. Trigger switch is not used in this function.

E:Off Delay(S Break)

Input voltage U must be applied continuously. When trigger switch S is clo-sed,relay contacts R change state. WWhen trigger switch S is opened, delay t bogins. When delay tis complete.contactsRreturntotheirshelfstate. If trigger switch Sis closed before time delay t is complete, then time is reset. When trigger switch Sis opened, the delay begins again, and relay contacts Rremain in their energizedstate.If input voltage U is removed. relay contacts R return to their shelf state.

F:Single Shot

Upon application of input voltage U,the relay is ready to accept trigger signal S.Upon application of the trigger signal S,the relay contacts R transfer and the preset time t begins. During time-out, the trigger signal Sis ignored. The relay resets by applying the trigger switch S when the relay is not energized.

G:Single Shot Trailing Edge(Non-Retriggerable)

Upon application of input voltage U, thee relay is ready to accept trigger signal S.Upon application of the trigger signal S,therelaycontactsRtransferandthe preset time t begins.At the end of the preset time t, the relay contacts R return to their normal condition unless the trigger switch Sis opened and closed prior to time outt(before preset time elapses).Continuouscyclingofthetriggerswitch SataratefasterthanthepresettimewillcausetherelaycontactsRtoremain closed.If input voltage U is removed,relay contacts R return to their shelf state

H:On/Off Delay

Input voltageU must be applied continuously. When trigger switch Sis closed,timedelaytbegins.Whentinhe delay tis complete,relay contacts Rchangestateandremaintransferred until trigger switch Sis opened. If input voltage U is removed,relaycontacts R return to their shelf state.

I:Latching relay

Input voltage U must be applied continuously. Output changes state with every trigger switch S closure.If input voltage U is removed,relay contacts Rreturn to their shelf state.

J:Pulse generator

Upon application of input voltage U.asingle output pulse of 0.5 seconds is delivered to relay after time delay t.Power must be removed and re-applied to repeat pulse. Trigger switch is not used in this function.



Free Shipping Over $199
  • Standard Shipping: Standard Shipping (12–18 Business Days)
  • Express Shipping: Expedited Shipping (5–9 Business Days)
  • Free Shipping: Orders over $199 qualify automatically
  • Tracking: Full tracking number provided for all orders
30-Day Return Policy
  • Returns: 30-day hassle-free return window
  • Condition: Items must be unused and in original packaging
  • Refund: Full refund processed within 3-5 business days
Why Choose Us?
  • Factory Direct: ISO/TS 16949 certified manufacturer
  • Quality: 100% electrical continuity tested before shipment
  • Experience: 15+ years in automotive connector industry
  • Support: Professional technical support available
Secure Payment Latest encryption technology
Money-Back Guarantee 30-day hassle-free returns
Quality Assured Factory certified products
Global Fast Shipping Worldwide express delivery

You may also like

Contact us

Subscribe to our emails

Be the first to know about new collections and special offers.