SPECIFICATIONS
Brand Name: VENGIM
Certification: CE
Contact Arrange: SPDT
Contact Load: Low Power
EU LVD Voltage: High voltage: Above 50Vac or 75Vdc
High-concerned chemical: none
Model Number: 531T
Origin: Mainland China
Power Source: Ac
Protect Feature: Sealed
Theory: Time Relay
Use: General Purpose
Voltage: 220V
is_customized: Yes
Description
The VG531T is a multi-function electronic time relay. It provides 10 functions with 8 time ranges from 0.1 seconds to 10 days. This time relay operates with a rated control supply voltage of 220V AC & 12-240V AC/DC and has a 1 C/O(SPDT) output rated at 5A/16A.
It has 10 functions
1. Power On Delay
2. Asymmetric Cycle(Starting Off)
3. Interval(Power On)
4. Off Delay
5. Single Shot (Retriggerable)
6. Asymmetric Cycle (Starting On)
7. Pulse (Generator)
8. Single Shot
9. On / Off Delay
10. Memory Latch
Technical data
– Rated supply voltage:220 V AC or 12-240 V AC/DC
– Rated frequency: 50/60 Hz
– Time delay range:0.1 second - 10 days
– Operating temperature:-20℃~+55℃
– Storage temperature:-30℃~+70℃
– Setting accuracy-full range:±5%
– Contacts type:1 C/O (SPDT)
– Rated current:5A or 16A/240 VAC,24 VDC (Resistive Load)
– Discrete Output Type:Relay
– Dimension:18mm × 65mm × 90mm

1. Power On Delay
When the input voltage U is applied, delay t begins. Relay contacts R change state after delay t is complete. Contacts R return to their shelf state when input voltage U is removed.
2. Asymmetric Cycle(Starting Off)
When the input voltage U is applied, delay t begins. When delay t is complete, relay contacts R change state for time delay t. This cycle will repeat until input voltage U is removed.
3. Interval(Power On)
When the input voltage U is applied, relay contacts R change state immediately, and delay t begins. When delay t is complete, contacts return to shelf state. When input voltage U is removed, contacts will also return to their state.
4. Off Delay
Input voltage U must be applied continuously. When trigger S is closed, relay contacts R change state. When trigger S is opened, delay t begins. When delay t is complete, contacts R returns to their shelf state. If trigger S is closed before time delay t is complete, then time is reset. When trigger S is opened, the delay begins again, and relay contacts remain in their energized state, if the input voltage U is removed, relay contacts R return to their shelf state.
5. Single Shot (Retriggerable)
Input voltage U must be applied continuously. When trigger S is closed, relay contacts R change state, delay t begins. When delay t is complete, contacts R return to their shelf state Whether S is opened or not. If trigger S is closed before time delay t is complete, then time is reset. When trigger S is opened, the delay begins again, and relay contacts remain in their energized state, if input voltage U is removed, relay contacts R return to their shelf state.
6. Asymmetric Cycle (Starting On)
When the input voltage U is applied, relay contacts R change state immediately and delay t begins. When delay t is complete, contacts return to shelf state for time delay t. This cycle will repeat until input voltage U is removed.
7. Pulse (Generator)
When the input voltage U is applied, delay t begins, relay will output a pulse signal of 0.5 seconds when delay t complete.
8. Single Shot
Input voltage U must be applied continuously. When trigger S is closed, relay contacts R change state, delay t begins. When delay t is complete, contacts R return to their shelf state Whether S is opened or not. If trigger S is closed before time delay t is complete, delay t is not reset When trigger S is opened again, and relay contacts remain in their energized state, if input voltage U is removed, relay contacts R return to their shelf state.
9. On / Off Delay
Input voltage U must be applied continuously. When trigger S is closed, delay t begins. When delay t is complete, relay contacts R change state and remain transferred until trigger S is opened. When trigger S is opened, delay t begins. When delay t is complete, contacts R return to their shelf state. If input voltage U is removed, relay contacts R return to their shelf state.
10. Memory Latch
Input voltage U must be applied continuously. Output changes state with every trigger S closure. If input voltage U is removed, relay contacts R return to their shelf state.



- Standard Shipping: Standard Shipping (12–18 Business Days)
- Express Shipping: Expedited Shipping (5–9 Business Days)
- Free Shipping: Orders over $199 qualify automatically
- Tracking: Full tracking number provided for all orders
- Returns: 30-day hassle-free return window
- Condition: Items must be unused and in original packaging
- Refund: Full refund processed within 3-5 business days
- Factory Direct: ISO/TS 16949 certified manufacturer
- Quality: 100% electrical continuity tested before shipment
- Experience: 15+ years in automotive connector industry