SPECIFICATIONS

Brand Name: XINGKECHUANG

Choice: yes

High-concerned chemical: none

Material: Polymer

Origin: Mainland China

Output: Switching Transducer

Theory: Capacitance Sensor

Type: Humidity Sensor

Use: Level Sensor

is_customized: Yes

semi_Choice: yes

1st. Overview
The intelligent non-contact liquid level sensor (hereinafter referred to as the liquid level sensor) adopts advanced signal
processing technology and high-speed signal processing chip, which breaks through the influence of container wall
thickness and realizes a true non-contact type of liquid level height in a closed container Detection. The liquid level
sensor (probe) is installed on the upper and lower sides of the outer wall of the container to be measured (the high and low
levels of the liquid level). The non-metallic container does not need to be opened, and the installation is simple and does
not affect production. It can detect the liquid level of various liquid toxic substances, strong acids, strong alkalis and
various liquids in high-pressure airtight containers. The liquid level sensor has no special requirements for the material of
the liquid medium and non-metallic container, and can be widely used. XKC-Y25-XXX series products are specially
developed for non-metallic container liquid level detection. This series of liquid level sensors are divided into four signal
output control methods, namely high and low level output interface, NPN output interface, PNP output interface, RS485
Output interface; the four signal output modes correspond to the following four models:


2nd.Product Features
1. XKC-Y25-XXX non-contact liquid level sensor is suitable for non-metallic containers. The product detects the liquid
through the detection signal through the non-metallic container and the outer wall of the pipeline, without direct contact
with the liquid, and will not be subject to strong acid, Corrosion damage caused by corrosive liquids such as strong alkalis
is not affected by scale or other debris, and it can be completed to detect whether there is liquid inside the container or
pipeline.
2. It can support high and low level output, NPN, PNP signal output (please refer to the manufacturer's instructions when
selecting the model).
3. The detection liquid level is accurate and stable, and cold, hot and boiling liquids can be detected.
4. Pure electronic circuit structure, non-mechanical working mode, stable performance and long lasting service life.
5. High stability, high sensitivity, strong anti-interference ability, free from external electromagnetic interference, special
treatment for power frequency interference and common mode interference, to be compatible with all 5-24V power
adapters on the market.
6. It has a wide range of application and strong sensing capability. It can penetrate and detect the liquid level in various
non-metallic containers, such as plastic, glass, ceramics and other containers. The sensing distance (container wall
thickness) can reach 20mm; liquid, powder, Particles can be detected.
7. Open collector output mode, wide voltage range (5-24V), suitable for connecting various circuits and product
applications.
 
3rd.Product Applications
The intelligent non-contact liquid level sensor uses the inductive capacitance of water to detect the presence of liquid.
When there is no liquid close to the sensor, the sensor has a certain static capacitance to the ground due to the presence of
distributed capacitance on the sensor. When the liquid level is slow When the sensor is slowly raised, the parasitic
capacitance of the liquid will be coupled to the static capacitance of the sensor, making the capacitance value of the
sensor larger. The changed capacitance signal is then input to the control IC for signal conversion, and the changed
capacitance is converted into a circuit signal The MCU calculates and judges the degree of the change in the analog
quantity. When the change exceeds a certain threshold, it is considered that the liquid level has reached the sensing point.
 


Free Shipping Over $199
  • Standard Shipping: Standard Shipping (12–18 Business Days)
  • Express Shipping: Expedited Shipping (5–9 Business Days)
  • Free Shipping: Orders over $199 qualify automatically
  • Tracking: Full tracking number provided for all orders
30-Day Return Policy
  • Returns: 30-day hassle-free return window
  • Condition: Items must be unused and in original packaging
  • Refund: Full refund processed within 3-5 business days
Why Choose Us?
  • Factory Direct: ISO/TS 16949 certified manufacturer
  • Quality: 100% electrical continuity tested before shipment
  • Experience: 15+ years in automotive connector industry
  • Support: Professional technical support available
Secure Payment Latest encryption technology
Money-Back Guarantee 30-day hassle-free returns
Quality Assured Factory certified products
Global Fast Shipping Worldwide express delivery

You may also like

Contact us

Subscribe to our emails

Be the first to know about new collections and special offers.