Description

SPECIFICATIONS

Brand Name: EC Buying

GP2Y1014AUVF PM2.5 sensor module: Dust/dust/air quality detection sensor module

High-concerned chemical: none

Material: Mixture

Origin: Mainland China

Output: Digital Sensor

Smart Electronics Experiment: Switch And Sensor For Arduino STM32

Theory: Optical Sensor

Type: Optical-Electronics Sensor

Use: Gas Sensor

ZH06-I/II/III/VI: ZH07 ZH06

is_customized: Yes

winsen: Can detect large particles Laser dust sensor module

Product description:
ZH07 is a general-purpose, miniaturized laser dust sensor
The module uses the principle of Mie scattering to
Detection of dust particles. Tested by professional algorithms and calibration
Process treatment, the sensor has good consistency and stability.
The sensor has both serial output and PWM output capabilities, which is convenient
Use, small size, easy to integrate application.
Features:
Good consistency
Real-time response
Accurate data
Low power consumption
Minimum resolution particle diameter 0.3 μm
Application:
air purifier,
Fresh air system,
Portable instrument,
Air quality monitor,
air conditioning,
Supporting consumer electronics and other equipment.
Parameter:
Detection particle size range: 0.3-10μm
Effective range: 0-1000μg/m⊃3;
Detection interval: 1s
PM2.5 detection accuracy: 0-100 μg/m⊃3;: ±15μg/m⊃3;; 101-1000 μg/m⊃3;: ±15% reading (test conditions: 25±2℃, 50±10%RH, TSI8530, cigarette, GBT18801- 2015)
Power-on stabilization time: 30s
Output data: UART_TTL output (3.3V level, default)
                     PWM output (3.3V level, default)
Working voltage: 4.8V~5.5V(DC)
Working current: <120mA
Current in power saving mode: <20mA
Response time: T90<30s
Working humidity: 0~80%RH (no condensation)
Working temperature: -10~60℃
Storage temperature: -30~70℃
Product description:
The ZH06 is a versatile, compact laser dust sensor module. Using the principle of Mie scattering, it is possible to detect dust particles present in the air, and to achieve good consistency and stability through professional algorithms and calibration detection processes. The sensor has the serial output and PWM output simultaneous output capability, which is convenient to use. Small size for easy integration.
Sensor characteristics:
1. Consistent
2. Real-time response
3. Accurate data
4. Low power consumption
5. Minimum resolution particle diameter 0.3 μm
Product parameters:
Detection particle size range: 0.3-10μm
Effective range: 0-1000μg/m3
Detection interval: 1s
PM2.5 detection accuracy: 0-100 μg/m3: ±15 μg/m3;
101-1000 μg/m3: ±15% reading (test conditions: 25±2°C, 50±10% RH, TSI8530, cigarette, GBT18801-2015)
Power-on stabilization time: 30s
Output data: UART_TTL output (3.3V level, default) PWM output (3.3V level, default)
Working voltage: 4.9V ~ 5.5V (DC)
Working current : <120mA
Sleep current: <20mA
Response time: T90<45s
Working humidity: 0~80%RH (no condensation)
Working temperature: -10~60°C
Storage temperature: -30 ~ 70 ° C
MTTF: continuous uninterrupted > 10000 h
Application:
1. Air purifier,
2. Fresh air system,
3. Portable instruments,
4. Air quality supervision,
5. Measuring equipment, air conditioning, smart home equipment and other places.
ZH06-I
Terminal description: 1.25T-8P connector, pin pitch 1.25mm, pin count: 8


Installation method:
The dust collection hole is the air inlet of the sensor, and needs to be in good contact with the outside air; the fan installation position is the air outlet of the sensor. When the sensor is installed, avoid strong airflow around the sensor; if it is unavoidable, try to keep the direction of the external airflow perpendicular to the direction of the airflow inside the sensor.
When designing the detection cavity of the whole machine, the effective area of the sampling port of the sensor should be fully considered to ensure the smoothness of the sampling gas path as much as possible. Small sampling area and excessive air resistance will seriously affect the accuracy of sensor data.
The arrow indicates the airflow perpendicular to the sensor surface
ZH06-Ⅱ
ZH06-Ⅲ
ZH06-IV 

1. It can detect low-level air pollution PM2.5, and can distinguish cigarettes and indoor/outdoor dust


2. Detect air pollution (air conditioner, air purifier, detector/portable)





Free Shipping Over $199
  • Standard Shipping: Standard Shipping (12–18 Business Days)
  • Express Shipping: Expedited Shipping (5–9 Business Days)
  • Free Shipping: Orders over $199 qualify automatically
  • Tracking: Full tracking number provided for all orders
30-Day Return Policy
  • Returns: 30-day hassle-free return window
  • Condition: Items must be unused and in original packaging
  • Refund: Full refund processed within 3-5 business days
Why Choose Us?
  • Factory Direct: ISO/TS 16949 certified manufacturer
  • Quality: 100% electrical continuity tested before shipment
  • Experience: 15+ years in automotive connector industry
  • Support: Professional technical support available
Secure Payment Latest encryption technology
Money-Back Guarantee 30-day hassle-free returns
Quality Assured Factory certified products
Global Fast Shipping Worldwide express delivery

You may also like

Contact us

Subscribe to our emails

Be the first to know about new collections and special offers.